Powered by GoogleTranslate

Inspection Detail

Inspection: 104211503 - Ziegler Painting & Sandblasting Co., Inc.

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 104211503
Report ID: 0751910
Date Opened: 04/07/1988

Site Address:
Ziegler Painting & Sandblasting Co., Inc.
Hubinger Co., One Progress Street
Keokuk, IA 52632

Mailing Address:
P. O. Box 421, Nauvoo, IL 62354

Union Status: NonUnion

SIC:1721

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/12/1988

Planning Guide: Safety-Construction

Emphasis: L:Scaffold

Case Closed: 01/18/1989


Related Activity
Type Activity Nr Safety Health
Accident 360740401
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $350 $0 $0 $0 $0 $350
Current Penalty $200 $0 $0 $0 $0 $200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260416 A03 05/02/1988 05/07/1988 $200 $350 $0 05/16/1988 F - Formal Settlement  

Investigation Summary

Investigation Nr: 14453633
Event: 04/06/1988
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU SCAFFOLD

FOUR EMPLOYEES WERE MOVING A TWO-POINT SUSPENSION SCAFFOLD IN A WESTERLY DIRECTION. THE HOIST CABLES FOR THE SCAFFOLD WERE STILL ATTACHED TO THE ROOF ANCHORS, AND THE SCAFFOLD WAS ON THE GROUND. THE SCAFFOLD WAS LOCATED 21 FEET, 3 INCHES OUT FROM THE BUILDING AND 29 FEET, 5 INCHES BELOW A 6000-OVERHEAD POWER LINE. AS THE SCAFFOLD WAS RAISED, THE HOIST CABLE ON THE WEST END CONTACTED THE OVERHEAD LINE AT ITS LOWEST POINT, ENERGIZING THE SCAFFOLD. ONE OF THE EMPLOYEES WAS ELECTROCUTED; THE OTHER THREE RECEIVED ELECTRIC SHOCKS AND WERE HOSPITALIZED FOR THEIR INJURIES.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTRIC SHOCK, E GI IB, ELECTROCUTED, TWO PT SUSP SCAFFOLD, SCAFFOLD RIGGING, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104211503 Hospitalized injury Electric Shock Painters, construction and maintenance
2 104211503 Hospitalized injury Electric Shock Painters, construction and maintenance
3 104211503 Fatality Electric Shock Painters, construction and maintenance
4 104211503 Hospitalized injury Electric Shock Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close