Powered by GoogleTranslate

Inspection Detail

Inspection: 104004445 - Randall Manufacturing Div Of Textron Inc

Inspection Information - Office: Indiana Department Of Labor

 

Inspection Nr: 104004445
Report ID: 0551800
Date Opened: 03/01/1988

Site Address:
Randall Manufacturing Div Of Textron Inc
101 Randall St
Greensburg, IN 47240

Mailing Address:
Attn Larry Montgomery 101 Randall St, Greensburg, IN 47240

Union Status: Union

SIC:3714

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/31/1988

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/08/1988


Related Activity
Type Activity Nr Safety Health
Accident 360470819
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1
Initial Penalty $720 $0 $0 $0 $0 $720
Current Penalty $240 $0 $0 $0 $0 $240
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100217 E01 I 05/10/1988 04/23/1988 $240 $720 $0 A - Amendment  
2. 02001 Other 19100217 C03 IVD 05/10/1988 04/23/1988 $0 $0 $0 A - Amendment Citation has been deleted.

Investigation Summary

Investigation Nr: 976233
Event: 02/04/1988
Employee's finger partially amputated in press

At approximately 4:25 p.m. on February 4, 1988, Employee #1, a press operator in Department 7 of Randall Manufacturing, a division of Textron, Inc., with only 40 days experience in manufacturing as a press operator, was operating a Federal 80-ton part-revolution mechanical power press for the first time. The Posson's pull-out device had a fracture of the right nylon cable clamp on the clip assembly due to metal fatigue. Employee #1 inadvertently activated a press cycle with the foot treadle while retrieving with her right hand a finished part from the lower die. Her left hand was pulled back, but the pull-out wristlet and cable on her right hand failed to function. She sustained an amputation of 3/8 in. of the first joint of her right index finger. Only the manual reaction of Employee #1 to yank her right hand back on her own averted a much more serious amputation. Both pull-out devices of both hands had been functioning properly before the accident. A combination of operator inexperience and mechanical failure of the safety pull-out system caused the accident.

Keywords: PULL BACK DEVICE, AMPUTATED, POWER PRESS, FINGER, EQUIPMENT FAILURE, INEXPERIENCE, PRESS OPERATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 104004445 Non Hospitalized injury Amputation Punching and stamping press machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close