Inspection Detail
Inspection: 103978789 - Sibley Machine & Foundry Corporation
Inspection Information - Office: Indiana Department Of Labor
Site Address:
Sibley Machine & Foundry Corporation
220 West Eckman Street
South Bend, IN 46614
Mailing Address:
Po Box 40, South Bend, IN 46624
Union Status: Union
SIC:3321
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/02/1988
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/03/1988
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360470496 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $480 | $0 | $0 | $0 | $0 | $480 |
| Current Penalty | $480 | $0 | $0 | $0 | $0 | $480 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100106 B06 | 07/12/1988 | 08/26/1988 | $480 | $480 | $0 | - |
Investigation Summary
At 4:00 a.m. on May 3, 1988, Employee #3 saw that a drum of ISOSET 4305, an epoxy resin solution, was smoking. Employee #3 summoned Employee #1, and the two of them removed the deflagrating drum from within the building to the outside. This process took ten minutes because of the fume emissions and the heat from the drum. Employees #1 and #3 continued working until 6:15 a.m. when they and thirteen other employees were transported by ambulance to a hospital and given a precautionary exam. Employees #1 through #15 were released without hospitalization. An electrically-energized barrel heater had been attached to the outside circumference of the drum. The chemicals in the drum had overheated and decomposed because the heater's rheostat control had been changed to 7.5 from the prescribed setting of 3.5.
Keywords: DRUM, SMOKING, TOXIC FUMES, CHEMICAL, HIGH TEMPERATURE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 2 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 3 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 4 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 5 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 6 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 7 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 8 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 9 | 103978789 | Non Hospitalized injury | Other | Supervisors, production occupations | ||
| 10 | 103978789 | Non Hospitalized injury | Other | Production inspectors, checkers and examiners | ||
| 11 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 12 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 13 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 14 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators | ||
| 15 | 103978789 | Non Hospitalized injury | Other | Furnace, kiln and oven operators |