Inspection Detail
Inspection: 103841102 - M Nakai Repair Service Ltd
Inspection Information - Office: Hi-E-Honolulu
Site Address:
M Nakai Repair Service Ltd
734 N King St
Honolulu, HI 96817
Mailing Address:
288 Mokauea St, Honolulu, HI 96819
Union Status: NonUnion
SIC:1799
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/17/1989
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 04/20/1989
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360106744 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 8 | 8 | ||||
| Current Violations | 8 | 8 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 1120003 | 04/05/1989 | 05/08/1989 | $0 | $0 | $0 | - | ||
| 2. | 01002 | Other | 1130006 A02 | 04/05/1989 | 04/10/1989 | $0 | $0 | $0 | - | ||
| 3. | 01003 | Other | 1210003 C01 | 04/05/1989 | 04/12/1989 | $0 | $0 | $0 | - | ||
| 4. | 01004 | Other | 1220004 B | 04/05/1989 | 04/12/1989 | $0 | $0 | $0 | - | ||
| 5. | 01005 | Other | 1260002 B02 | 04/05/1989 | 04/10/1989 | $0 | $0 | $0 | - | ||
| 6. | 01006 | Other | 1270006 B01 | 04/05/1989 | 05/08/1989 | $0 | $0 | $0 | - | ||
| 7. | 01007 | Other | 1410002 B11 C | 04/05/1989 | 04/12/1989 | $0 | $0 | $0 | - | ||
| 8. | 01008 | Other | 1410006 C02 | 04/05/1989 | 04/10/1989 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1 was cutting a 55 gallon drum when it exploded. He sustained a broken nose and forehead lacerations. Employee #1 indicated that he had not followed the established company procedure to test for combustible gas, and, if the results were positive, to clean and vent a drum before cutting it.
Keywords: HEAD, FLAMMABLE VAPORS, WORK RULES, DRUM, CONSTRUCTION, EXPLOSION, LACERATION, FACE, CUTTING AND BURNING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103841102 | Hospitalized injury | Fracture | Plumbers, pipefitters and steamfitters |