Inspection Detail
Inspection: 103820486 - Apollo Systems Inc
Inspection Information - Office: Hi-E-Honolulu
Site Address:
Apollo Systems Inc
1728 Homerule St
Honolulu, HI 96819
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:1799
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/10/1989
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 01/24/1990
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360106546 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 1 | 5 | |||
| Current Violations | 4 | 1 | 5 | |||
| Initial Penalty | $400 | $0 | $0 | $0 | $0 | $400 |
| Current Penalty | $400 | $0 | $0 | $0 | $0 | $400 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 1100002 A03 | 10/23/1989 | 09/19/1989 | $100 | $100 | $0 | - | ||
| 2. | 01002 | Serious | 1100002 B01 | 10/23/1989 | 01/15/1990 | $100 | $100 | $0 | P - Petition to Mod Abatement | ||
| 3. | 01003 | Serious | 1130002 A | 10/23/1989 | 01/15/1990 | $100 | $100 | $0 | P - Petition to Mod Abatement | ||
| 4. | 01004A | Serious | 1410002 B01 | 10/23/1989 | 09/19/1989 | $100 | $100 | $0 | - | ||
| 5. | 01004B | Serious | 1410002 B02 | 10/23/1989 | 09/19/1989 | $0 | $0 | $0 | - | ||
| 6. | 02001 | Other | 2030005 A | 10/23/1989 | 01/22/1990 | $0 | $0 | $0 | P - Petition to Mod Abatement |
Investigation Summary
An employee was cleaning a pair of scissors in a parts cleaner. The parts cleaner had an electric pump. When the employee was finished, he operated the pump switch, which was located on the outside of the cleaner. An electric arc from the switch ignited the cleaning solvent in the parts cleaner. Two other employees tried to move the burning parts cleaner and tipped it over, spilling the burning solution. One of the employees sustained second- and third-degree burns over 90 percent of his body. The other employee sustained second-degree burns on his lower right leg and hand. Both employees were hospitalized.
Keywords: BURN, E GI V, ELECTRIC ARC, ELECTRICAL, ELECTRIC SWITCH, FLAMMABLE LIQUID, CLEANING FLUID, EQUIPMENT APPROVAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103820486 | Hospitalized injury | Burn/Scald(Heat) | Managers and administrators, n.e.c | ||
| 2 | 103820486 | Hospitalized injury | Burn/Scald(Heat) | Supervisors, n.e.c. |
Translate