Inspection Detail
Inspection: 103605010 - Turtle Tours
Inspection Information - Office: San Francisco Ro
Site Address:
Turtle Tours
674a South Marine Drive
Tamuning, GU 96911
Mailing Address:
P.O. Box 6098, Tamuning, GU 96931
Union Status: NonUnion
SIC:4141
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/11/2000
Emphasis:
Case Closed: 11/13/2000
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360400998 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $2,200 | $0 | $0 | $0 | $0 | $2,200 |
Current Penalty | $2,200 | $0 | $0 | $0 | $0 | $2,200 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 10/11/2000 | 10/19/2000 | $1,375 | $1,375 | $0 | - | ||
2. | 01002 | Serious | 19100106 G08 | 10/11/2000 | 10/16/2000 | $825 | $825 | $0 | - |
Investigation Summary
A bus washer had cleaned a bus and had driven it to a parking area at a touring company's bus compound. He was parking the bus between a van and another bus near a utility pole. As he was backing the bus, it ran over the guy for the pole. The utility pole moved, and one of the phase conductors of an overhead power line supported by the pole broke. The conductor started a fire when it hit the ground. The bus washer was electrocuted as he tried to extinguish the fire with a wooden stick.
Keywords: E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, FIRE, GUY, UNTRAINED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 103605010 | Fatality | Electric Shock | Vehicle washers and equipment cleaners |