Inspection Detail
Inspection: 103577847 - Charter Builders Inc.
Inspection Information - Office: Corpus Christi Area Office
Site Address:
Charter Builders Inc.
Glenn Chase Nas, West Side Bldg. K
Beeville, TX 78102
Mailing Address:
1501 Lbj Freeway, Suite 700, Dallas, TX 75234
Union Status: NonUnion
SIC:1542
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/20/1994
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 08/16/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360158752 | ||
| Referral | 901565838 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $16,000 | $0 | $0 | $0 | $0 | $16,000 |
| Current Penalty | $6,000 | $0 | $0 | $0 | $0 | $6,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19260020 B02 | 12/15/1994 | 12/19/1994 | $2,000 | $4,000 | $0 | 01/11/1995 | F - Formal Settlement | |
| 2. | 01001B | Serious | 19260021 B02 | 12/15/1994 | 01/17/1995 | $0 | $0 | $0 | 01/11/1995 | F - Formal Settlement | |
| 3. | 01002 | Serious | 19260404 B01 I | 12/15/1994 | 12/19/1994 | $2,000 | $4,000 | $0 | 01/11/1995 | F - Formal Settlement | |
| 4. | 01003 | Serious | 19260404 F06 | 12/15/1994 | 12/19/1994 | $0 | $4,000 | $0 | 01/11/1995 | F - Formal Settlement | Citation has been deleted. |
| 5. | 01004 | Serious | 19260405 G02 IV | 12/15/1994 | 12/19/1994 | $2,000 | $4,000 | $0 | 01/11/1995 | F - Formal Settlement |
Investigation Summary
Two employees were working on a scissor lift, installing closure plates. One of them was sitting on the lift's guardrail with his right hand holding the purling. He received an electric shock and was frozen to the purling. He then collapsed into the scissor lift; he was electrocuted. The other employee also received an electric shock as he was trying to notch a clip. (Despite the injury, he was not listed on an injury line on the original form.) He dropped the nibbler he was using as a result of the electric shock. The employees were using defective equipment; however, the original abstract did not note exactly which equipment was defective.
Keywords: ELECTRICAL, MOBILE SCAFFOLD, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC SHOCK, ELEC PORT TOOL--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103577847 | Fatality | Electric Shock | Occupation not reported |
Translate