Inspection Detail
Inspection: 103562344 - Dicks Diving Service
Inspection Information - Office: Dallas Area Office
Site Address:
Dicks Diving Service
701 North High
Longview, TX 75601
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7389
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/13/1991
Emphasis:
Case Closed: 05/21/1991
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360458996 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 2 | ||||
Initial Penalty | $450 | $0 | $0 | $0 | $0 | $450 |
Current Penalty | $225 | $0 | $0 | $0 | $0 | $225 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100424 C02 | 04/15/1991 | 04/18/1991 | $225 | $225 | $0 | - | ||
2. | 01002 | Serious | 19100424 C04 I | 04/15/1991 | 05/02/1991 | $0 | $225 | $0 | I - Informal Settlement | ||
3. | 02001 | Other | 19100420 A | 04/15/1991 | 05/02/1991 | $0 | $0 | $0 | I - Informal Settlement | Citation has been deleted. |
Investigation Summary
Employee #1 apparently ran out of air in his scuba, probably because a second stage regulator on an octopus either came off or was pulled off, causing a rapid loss of his air supply. The octopus is a spare mouthpiece and line hooked in the same place as the primary line and mouthpiece used by the diver. It gives air to a diver in peril and is sometimes carried in a pocket on the dive vest, or in some cases flailing free, as was the case in this incident. Employee #1, who was diving alone, had neither a J valve to warn him of low remaining air, nor an independent tank supply, and his line was not tended. He was down about 20 to 30 minutes before anyone went in to check on him. Employee #1 did have a pressure gauge used in place of the J valve. Employee #1 drowned.
Keywords: OXYGEN DEFICIENCY, SCUBA, WORK RULES, ALARM, DIVING, VALVE, DROWN, ACCIDENTAL DISCHARGE, DIVER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 103562344 | Fatality | Asphyxia | Occupation not reported |