Inspection Detail
Inspection: 103489241 - Henson Robinson Co.
Inspection Information - Office: Peoria Area Office
Site Address:
Henson Robinson Co.
Urbana Middle School, S. Vine St.
Urbana, IL 61801
Mailing Address:
2015 Clear Lake Avenue, Springfield, IL 62703
Union Status: Union
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/16/1992
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 05/22/1992
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360686133 |
Investigation Summary
Employee #1 was lighting the pilot light on a boiler when an accumulation of gas exploded. He was partially decapitated and killed when he was struck by the boiler door.
Keywords: PILOT LIGHT, FLAMMABLE VAPORS, WORK RULES, BOILER, CONSTRUCTION, EXPLOSION, STRUCK BY, FLYING OBJECT, DECAPITATED, DOOR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103489241 | Fatality | Other | Occupation not reported |
Translate