Inspection Detail
Inspection: 103483558 - Central Industrial Electric Co., Inc.
Inspection Information - Office: Little Rock Area Office
Site Address:
Central Industrial Electric Co., Inc.
One Medical Park Drive
Benton, AR 72015
Mailing Address:
1606 Maumelle Blvd., North Little Rock, AR 72118
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/25/1990
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 10/31/1990
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360432629 |
Investigation Summary
Employees #1 and #2 were working on a two-point suspended scaffold. Safety lines had been secured to the top of the structure and dropped over the side. Safety belts and lanyards were on the scaffold but were not worn by the employees. Apparently, no inspection was made of the two stirrups prior to their use. The overspeed brake on one stirrup was completely missing a little rubber wheel that would have detected a fall. The other stirrup had only 40 percent of the rubber wheel remaining. It has not been determined why one end of the scaffold fell and the other fell 18 ft before the overspeed brake (with 40 percent of the rubber wheel) caught. The impact straightened out a 1/2 in. diameter steel hook on the outrigger above, allowing the one stirrup and a scaffold board to fall about 65 ft to a roof. Employee #2 landed on the roof, sustaining multiple broken bones and internal injuries. Employee #1 fell an additional 12 1/2 ft to the ground, sustained multiple broken bones, and died shortly afterward.
Keywords: FALL PROTECTION, STRUCK AGAINST, SCAFFOLD COLLAPSE, BRAKE, TWO PT SUSP SCAFFOLD, FALL, WORK RULES, SCAFFOLDING, ROOF, CONSTRUCTION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 103483558 | Occupation Not Listed |