Powered by GoogleTranslate

Inspection Detail

Inspection: 103475588 - Milprint, Inc.

Inspection Information - Office: Milwaukee Area Office

 

Inspection Nr: 103475588
Report ID: 0523400
Date Opened: 10/14/1987

Site Address:
Milprint, Inc.
4200 N. Holton Street
Milwaukee, WI 53212

Mailing Address:
P.O. Box 454, Milwaukee, WI 53201

Union Status: Union

SIC:2672

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/06/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 02/17/1988


Related Activity
Type Activity Nr Safety Health
Accident 360116255
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 18 23
Current Violations 5 18 23
Initial Penalty $1,440 $0 $0 $60 $0 $1,500
Current Penalty $625 $0 $0 $125 $0 $750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100106 E02 IIB 11/19/1987 12/24/1987 $125 $300 $0 I - Informal Settlement  
2. 01002 Serious 19100106 E02 IVA 11/19/1987 11/22/1987 $125 $240 $0 I - Informal Settlement  
3. 01003A Serious 19100106 E02 IVD 11/19/1987 11/22/1987 $125 $300 $0 I - Informal Settlement  
4. 01003B Serious 19100106 E06 II 11/19/1987 11/22/1987 $0 $0 $0 -  
5. 01003C Serious 19100106 E02 IIB 11/19/1987 12/11/1987 $0 $0 $0 -  
6. 01004 Serious 19100212 A01 11/19/1987 12/14/1987 $125 $240 $0 I - Informal Settlement  
7. 01005 Serious 19100303 G02 I 11/19/1987 11/22/1987 $125 $360 $0 I - Informal Settlement  
8. 02001 Other 19040002 A 11/19/1987 12/31/1987 $125 $60 $0 I - Informal Settlement  
9. 02002 Other 19100022 A02 11/19/1987 12/09/1987 $0 $0 $0 -  
10. 02003 Other 19100022 B01 11/19/1987 11/22/1987 $0 $0 $0 -  
11. 02004 Other 19100106 E09 III 11/19/1987 12/07/1987 $0 $0 $0 -  
12. 02005 Other 19100106 E09 IV 11/19/1987 11/22/1987 $0 $0 $0 -  
13. 02006 Other 19100108 C05 11/19/1987 11/27/1987 $0 $0 $0 -  
14. 02007 Other 19100141 D02 II 11/19/1987 12/17/1987 $0 $0 $0 -  
15. 02008 Other 19100178 K01 11/19/1987 11/27/1987 $0 $0 $0 -  
16. 02009 Other 19100184 E01 11/19/1987 01/07/1988 $0 $0 $0 -  
17. 02010 Other 19100184 E03 I 11/19/1987 01/04/1988 $0 $0 $0 -  
18. 02011 Other 19100212 A05 11/19/1987 11/27/1987 $0 $0 $0 -  
19. 02012 Other 19100213 B03 11/19/1987 12/14/1987 $0 $0 $0 -  
20. 02013 Other 19100219 E03 I 11/19/1987 12/14/1987 $0 $0 $0 -  
21. 02014 Other 19100303 G01 II 11/19/1987 11/22/1987 $0 $0 $0 -  
22. 02015 Other 19100304 F05 V 11/19/1987 11/27/1987 $0 $0 $0 -  
23. 02016 Other 19100305 B02 11/19/1987 11/27/1987 $0 $0 $0 -  
24. 02017 Other 19101200 F04 11/19/1987 01/15/1988 $0 $0 $0 I - Informal Settlement  
25. 02018 Other 19101200 F04 II 11/19/1987 12/06/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14499636
Event: 10/13/1987
EXPLOSION - STATIC ELECTRICITY IGNITED FLAMMABLE VAPORS

AN EMPLOYEE WAS USING AN AIR DRIVEN PUMP TO TRANSFER A 50/50-MIXTURE OF N-PROPYL ACETATE AND VM&P NAPHTHA FROM A 55-GALLON DRUM INTO AN OPEN 2-GALLON PLASTIC PAIL. THE TWO HOSES FROM THE PUMP WERE NON-CONDUCTIVE, AND EACH HAD A METAL NIPPLE ON ITS END. THE PUMP WAS GROUNDED, AND SO WAS THE BARREL. HOWEVER, NEITHER NIPPLE WAS SEPARATELY GROUNDED; THEREFORE, SINCE NON-CONDUCTIVE HOSES WERE USED, THE TRANSFER SYSTEM WAS NOT BONDED THROUGHOUT. THE PLASTIC PAIL WAS SITTING ON TOP OF THE BARREL; AND ONE HOSE WAS PLACED IN THE BARREL, AND THE OTHER IN THE PAIL. THE EMPLOYEE HAD PERFORMED THIS OPERATION "HUNDREDS OF TIMES" WITHOUT INCIDENT, BUT THIS TIME A DISCHARGE OF STATIC ELECTRICITY IGNITED THE FLAMMABLE VAPORS ABOVE THE OPEN PAIL. THE EMPLOYEE, WHO HAD SEEN THE LIQUID IN THE PAIL BURNING, WENT TO GET A FIRE EXTINGUISHER THAT WAS LOCATED LESS THAN 25 FEET AWAY. THE BARREL OF SOLVENT THEN EXPLODED, SPILLING BURNING LIQUID OVER A WIDE AREA. THE AUTOMATIC SPRINKLER SYSTEM FOR THE AREA AND THE CARBON DIOXIDE SYSTEM FOR A NEARBY PRESS ACTIVATED AND EXTINGUISHED THE FLAMES BEFORE IT COULD SPREAD TO OTHER BARRELS IN THE AREA. (THE OTHER BARRELS CONTAINED ETHYL ALCOHOL, ISOPROPYL ACETATE, AND OTHER SOLVENTS.) THE EMPLOYEE RECEIVED MINOR BURNS AND WAS HOSPITALIZED FOR HIS INJURIES. NINE OTHER EMPLOYEES IN THE AREA WERE HOSPITALIZED FOR SMOKE INHALATION.

Keywords: BURN, STATIC ELECTRICITY, ELECTRICAL, FLAMMABLE VAPORS, E GI VII, FIRE, NAPHTHA, EXPLOSION, BONDING, SMOKE INHALATION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103475588 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 103475588 Hospitalized injury Burn(Chemical) Occupation not reported
3 103475588 Hospitalized injury Burn(Chemical) Occupation not reported
4 103475588 Hospitalized injury Burn(Chemical) Occupation not reported
5 103475588 Hospitalized injury Burn(Chemical) Occupation not reported
6 103475588 Hospitalized injury Burn(Chemical) Occupation not reported
7 103475588 Hospitalized injury Burn(Chemical) Occupation not reported
8 103475588 Hospitalized injury Burn(Chemical) Occupation not reported
9 103475588 Hospitalized injury Burn(Chemical) Occupation not reported
10 103475588 Hospitalized injury Burn(Chemical) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close