Inspection Detail
Inspection: 103475588 - Milprint, Inc.
Inspection Information - Office: Milwaukee Area Office
Site Address:
Milprint, Inc.
4200 N. Holton Street
Milwaukee, WI 53212
Mailing Address:
P.O. Box 454, Milwaukee, WI 53201
Union Status: Union
SIC:2672
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/06/1987
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 02/17/1988
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360116255 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 18 | 23 | |||
| Current Violations | 5 | 18 | 23 | |||
| Initial Penalty | $1,440 | $0 | $0 | $60 | $0 | $1,500 |
| Current Penalty | $625 | $0 | $0 | $125 | $0 | $750 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100106 E02 IIB | 11/19/1987 | 12/24/1987 | $125 | $300 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100106 E02 IVA | 11/19/1987 | 11/22/1987 | $125 | $240 | $0 | I - Informal Settlement | ||
| 3. | 01003A | Serious | 19100106 E02 IVD | 11/19/1987 | 11/22/1987 | $125 | $300 | $0 | I - Informal Settlement | ||
| 4. | 01003B | Serious | 19100106 E06 II | 11/19/1987 | 11/22/1987 | $0 | $0 | $0 | - | ||
| 5. | 01003C | Serious | 19100106 E02 IIB | 11/19/1987 | 12/11/1987 | $0 | $0 | $0 | - | ||
| 6. | 01004 | Serious | 19100212 A01 | 11/19/1987 | 12/14/1987 | $125 | $240 | $0 | I - Informal Settlement | ||
| 7. | 01005 | Serious | 19100303 G02 I | 11/19/1987 | 11/22/1987 | $125 | $360 | $0 | I - Informal Settlement | ||
| 8. | 02001 | Other | 19040002 A | 11/19/1987 | 12/31/1987 | $125 | $60 | $0 | I - Informal Settlement | ||
| 9. | 02002 | Other | 19100022 A02 | 11/19/1987 | 12/09/1987 | $0 | $0 | $0 | - | ||
| 10. | 02003 | Other | 19100022 B01 | 11/19/1987 | 11/22/1987 | $0 | $0 | $0 | - | ||
| 11. | 02004 | Other | 19100106 E09 III | 11/19/1987 | 12/07/1987 | $0 | $0 | $0 | - | ||
| 12. | 02005 | Other | 19100106 E09 IV | 11/19/1987 | 11/22/1987 | $0 | $0 | $0 | - | ||
| 13. | 02006 | Other | 19100108 C05 | 11/19/1987 | 11/27/1987 | $0 | $0 | $0 | - | ||
| 14. | 02007 | Other | 19100141 D02 II | 11/19/1987 | 12/17/1987 | $0 | $0 | $0 | - | ||
| 15. | 02008 | Other | 19100178 K01 | 11/19/1987 | 11/27/1987 | $0 | $0 | $0 | - | ||
| 16. | 02009 | Other | 19100184 E01 | 11/19/1987 | 01/07/1988 | $0 | $0 | $0 | - | ||
| 17. | 02010 | Other | 19100184 E03 I | 11/19/1987 | 01/04/1988 | $0 | $0 | $0 | - | ||
| 18. | 02011 | Other | 19100212 A05 | 11/19/1987 | 11/27/1987 | $0 | $0 | $0 | - | ||
| 19. | 02012 | Other | 19100213 B03 | 11/19/1987 | 12/14/1987 | $0 | $0 | $0 | - | ||
| 20. | 02013 | Other | 19100219 E03 I | 11/19/1987 | 12/14/1987 | $0 | $0 | $0 | - | ||
| 21. | 02014 | Other | 19100303 G01 II | 11/19/1987 | 11/22/1987 | $0 | $0 | $0 | - | ||
| 22. | 02015 | Other | 19100304 F05 V | 11/19/1987 | 11/27/1987 | $0 | $0 | $0 | - | ||
| 23. | 02016 | Other | 19100305 B02 | 11/19/1987 | 11/27/1987 | $0 | $0 | $0 | - | ||
| 24. | 02017 | Other | 19101200 F04 | 11/19/1987 | 01/15/1988 | $0 | $0 | $0 | I - Informal Settlement | ||
| 25. | 02018 | Other | 19101200 F04 II | 11/19/1987 | 12/06/1987 | $0 | $0 | $0 | - |
Investigation Summary
AN EMPLOYEE WAS USING AN AIR DRIVEN PUMP TO TRANSFER A 50/50-MIXTURE OF N-PROPYL ACETATE AND VM&P NAPHTHA FROM A 55-GALLON DRUM INTO AN OPEN 2-GALLON PLASTIC PAIL. THE TWO HOSES FROM THE PUMP WERE NON-CONDUCTIVE, AND EACH HAD A METAL NIPPLE ON ITS END. THE PUMP WAS GROUNDED, AND SO WAS THE BARREL. HOWEVER, NEITHER NIPPLE WAS SEPARATELY GROUNDED; THEREFORE, SINCE NON-CONDUCTIVE HOSES WERE USED, THE TRANSFER SYSTEM WAS NOT BONDED THROUGHOUT. THE PLASTIC PAIL WAS SITTING ON TOP OF THE BARREL; AND ONE HOSE WAS PLACED IN THE BARREL, AND THE OTHER IN THE PAIL. THE EMPLOYEE HAD PERFORMED THIS OPERATION "HUNDREDS OF TIMES" WITHOUT INCIDENT, BUT THIS TIME A DISCHARGE OF STATIC ELECTRICITY IGNITED THE FLAMMABLE VAPORS ABOVE THE OPEN PAIL. THE EMPLOYEE, WHO HAD SEEN THE LIQUID IN THE PAIL BURNING, WENT TO GET A FIRE EXTINGUISHER THAT WAS LOCATED LESS THAN 25 FEET AWAY. THE BARREL OF SOLVENT THEN EXPLODED, SPILLING BURNING LIQUID OVER A WIDE AREA. THE AUTOMATIC SPRINKLER SYSTEM FOR THE AREA AND THE CARBON DIOXIDE SYSTEM FOR A NEARBY PRESS ACTIVATED AND EXTINGUISHED THE FLAMES BEFORE IT COULD SPREAD TO OTHER BARRELS IN THE AREA. (THE OTHER BARRELS CONTAINED ETHYL ALCOHOL, ISOPROPYL ACETATE, AND OTHER SOLVENTS.) THE EMPLOYEE RECEIVED MINOR BURNS AND WAS HOSPITALIZED FOR HIS INJURIES. NINE OTHER EMPLOYEES IN THE AREA WERE HOSPITALIZED FOR SMOKE INHALATION.
Keywords: BURN, STATIC ELECTRICITY, ELECTRICAL, FLAMMABLE VAPORS, E GI VII, FIRE, NAPHTHA, EXPLOSION, BONDING, SMOKE INHALATION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103475588 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 103475588 | Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 3 | 103475588 | Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 4 | 103475588 | Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 5 | 103475588 | Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 6 | 103475588 | Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 7 | 103475588 | Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 8 | 103475588 | Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 9 | 103475588 | Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 10 | 103475588 | Hospitalized injury | Burn(Chemical) | Occupation not reported |