Close Conference: 10/26/1992
Emphasis:
Case Closed: 07/26/1993
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 901690800 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 5 | 5 | ||||
Current Violations | 5 | 5 | ||||
Initial Penalty | $4,800 | $0 | $0 | $0 | $0 | $4,800 |
Current Penalty | $4,000 | $0 | $0 | $0 | $0 | $4,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100106 E02 II | 12/14/1992 | 12/18/1992 | $700 | $1,500 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100106 E06 I | 12/14/1992 | 03/01/1993 | $1,500 | $1,500 | $0 | I - Informal Settlement | ||
3. | 01003A | Serious | 19100147 C04 I | 12/14/1992 | 04/01/1993 | $450 | $450 | $0 | P - Petition to Mod Abatement | ||
4. | 01003B | Serious | 19100147 C07 IV | 12/14/1992 | 04/01/1993 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
5. | 01004 | Serious | 19100157 G02 | 12/14/1992 | 04/01/1993 | $600 | $600 | $0 | P - Petition to Mod Abatement | ||
6. | 01005 | Serious | 19101200 H | 12/14/1992 | 04/01/1993 | $750 | $750 | $0 | P - Petition to Mod Abatement |
Investigation Summary
Employee #1 was in a workshop preparing to cut a nut off a piece of equipment with a torch. When he lit the torch, he ignited vapors that had escaped from two 5-gal cans of Tannergas, a flammable liquid, which had been stored under a workbench approximately 3 ft away. One of the cans had a hole poked through the top to ease pouring. The vapors had escaped through the hole. Employee #1 sustained third-degree burns over 60 percent of his lower body. Employees #2 and #3 were treated for smoke inhalation.
Keywords: BURN, FLAMMABLE VAPORS, FIRE, TORCH, EXPLOSION, SMOKE INHALATION, CUTTING AND BURNING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 103451266 | Non Hospitalized injury | Asphyxia | Occupation not reported | ||
2 | 103451266 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||