Powered by GoogleTranslate

Inspection Detail

Inspection: 103435905 - Petroleum Engineers International Inc.

Inspection Information - Office: Baton Rouge Area Office

 

Inspection Nr: 103435905
Report ID: 0625700
Date Opened: 08/18/1994

Site Address:
Petroleum Engineers International Inc.
Nabors Rig #570, Off Hwy 87
Jeanerette, LA 70544

Mailing Address:
Po Box 52588, Lafayette, LA 70505

Union Status: NonUnion

SIC:8711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 09/07/1994

Emphasis:

Case Closed: 02/07/1995


Related Activity
Type Activity Nr Safety Health
Accident 361124753
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $900 $0 $0 $0 $0 $900
Current Penalty $600 $0 $0 $0 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19101200 E01 10/11/1994 11/20/1994 $300 $450 $0 I - Informal Settlement  
2. 01002 Serious 19101200 H 10/11/1994 11/04/1994 $300 $450 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170080162
Event: 08/16/1994
Employee dies when struck in head by vent pipe

At approximately 10:30 p.m. on August 16, 1994, Employee #1, a consultant engineer with Petroleum Engineers International, Inc., was operating a choke lever on a control unit which opened and closed the infeed lines to a degasser unit at Nabors' rig #570 near Jerrette, LA. Employee #1 and coworkers were trying to bleed off the pressure on the casing pipe in the hole. The casing pipe had been under 3,800 pounds of pressure throughout the course of the day, and the well had kicked. It was decided to use the degassing method to bleed off the pressure. As Employee #1 operated the lever, there was a sudden pressure surge down the line to the degasser equipment. The vent pipe, measuring 6 in. in diameter by 13 ft 4 in. long, blew off the degasser. It flew up in the air and came down, fatally striking the employee in the head. This equipment is used regularly on oil/gas rigs for the purpose of venting off the gas from the drilling head. Employee #1 had experience in working around this equipment. The vent pipe that blew off was screwed on as opposed to being welded onto the degasser apparatus.

Keywords: HEAD, VENTING, ELDERLY, PIPE, STRUCK BY, FLYING OBJECT, PRESSURE RELEASE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103435905 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close