Inspection Detail
Inspection: 103379343 - All Season Heating & Air Conditioning
Inspection Information - Office: Cincinnati Area Office
Site Address:
All Season Heating & Air Conditioning
124 Highland Ave
Mcdermott, OH 45652
Mailing Address:
1819 Galena Pike West, Portsmouth, OH 45663
Union Status: NonUnion
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/12/1994
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 10/31/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360169593 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 3 | 8 | |||
| Current Violations | 5 | 3 | 8 | |||
| Initial Penalty | $4,500 | $0 | $0 | $0 | $0 | $4,500 |
| Current Penalty | $2,925 | $0 | $0 | $0 | $0 | $2,925 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260020 B01 | 07/21/1994 | 08/15/1994 | $585 | $750 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19260021 B02 | 07/21/1994 | 08/04/1994 | $585 | $750 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19260404 B01 I | 07/21/1994 | 07/28/1994 | $585 | $750 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19260404 F06 | 07/21/1994 | 07/26/1994 | $585 | $750 | $0 | I - Informal Settlement | ||
| 5. | 01005 | Serious | 19260416 A03 | 07/21/1994 | 07/26/1994 | $585 | $1,500 | $0 | I - Informal Settlement | ||
| 6. | 02001 | Other | 19030002 A01 | 07/21/1994 | 07/26/1994 | $0 | $0 | $0 | - | ||
| 7. | 02002 | Other | 19040008 A | 07/21/1994 | 07/26/1994 | $0 | $0 | $0 | - | ||
| 8. | 02003 | Other | 19260059 E01 | 07/21/1994 | 08/15/1994 | $0 | $0 | $0 | - |
Investigation Summary
An employee was operating a metal-encased 0.5-inch electric drill with a 2.5-inch hole saw attachment. He was cutting a hole in the outside wall of a residence as part of the installation of a heat pump. He was drilling through an area between the floor joist and the base plate. The drill bit cut into a 120-volt non-metallic sheathed cable that was part of the premises wiring. The employee, who was perspiring and who was kneeling on the ground, received an electric shock as a result of the ground fault and could not let go of the drill. He was transported to a local hospital by emergency medical services. He was revived several times during transport, but was pronounced dead by ventricular fibrillation on arrival at the hospital.
Keywords: ELECTRICAL, E GI VI, ELECTRIC CABLE, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC DRILL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103379343 | Fatality | Electric Shock | Occupation not reported |
Translate