Powered by GoogleTranslate

Inspection Detail

Inspection: 103312591 - Culligan Water Conditioning Inc.

Inspection Information - Office: Milwaukee Area Office

 

Inspection Nr: 103312591
Report ID: 0523400
Date Opened: 07/31/1989

Site Address:
Culligan Water Conditioning Inc.
665 South Kane Street
Burlington, WI 53105

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/03/1989

Emphasis:

Case Closed: 01/02/1990


Related Activity
Type Activity Nr Safety Health
Accident 360116784
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19101200 E01 08/18/1989 12/19/1989 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14499958
Event: 07/28/1989
ELECTRIC SHOCK - CONTACT WITH LIVE PARTS THRU PIPE CUTTER

AN EMPLOYEE OF A WATER SOFTENER FIRM WAS INSTALLING A WATER SOFTENER AT A MOBILE HOME. HE WAS KNEELING ON WET GROUND, USING A PIPE CUTTER TO CUT A COPPER WATER PIPE. A PIPE HEATER CORD WAS WRAPPED AROUND THE PIPE WHERE IT WAS BEING CUT. THE HEATER CORD WAS PLUGGED INTO AN OUTLET 2 FEET AWAY FROM THE EMPLOYEE. IN CUTTING THE PIPE, THE EMPLOYEE CUT INTO THE 120-VOLT HEATER CORD AND WAS ELECTROCUTED. THE EMPLOYEE WAS FOUND SOME TIME LATER, AND CURRENT WAS STILL PASSING THROUGH HIM WHEN THE RESCUE SERVICE ARRIVED.

Keywords: E GI IV, ELECTRICAL, ELECTROCUTED, PLUMBING, ELECTRIC CORD, METAL PIPE, ELEC EQUIPMENT--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103312591 Fatality Electric Shock Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.