Powered by GoogleTranslate

Inspection Detail

Inspection: 103233185 - Folzenolgen Construction

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 103233185
Report ID: 0522000
Date Opened: 03/26/1997

Site Address:
Folzenolgen Construction
7212 Harrison Ave
Cincinnati, OH 45247

Mailing Address:
3321 Epworth Avenue, Cincinnati, OH 45211

Union Status: NonUnion

SIC:1794

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/26/1997

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 01/26/1998


Related Activity
Type Activity Nr Safety Health
Accident 361915952
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $2,500 $0 $0 $0 $0 $2,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B02 07/08/1997 07/21/1997 $1,000 $1,500 $0 I - Informal Settlement  
2. 01002 Serious 19260021 B02 07/08/1997 07/21/1997 $1,000 $1,500 $0 I - Informal Settlement  
3. 01003 Serious 19260550 A15 I 07/08/1997 07/11/1997 $500 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 700807
Event: 03/20/1997
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LOAD LINE

Three employees were using a rubber-tired, hydraulic, truck-mounted crane to remove boring equipment from a boring pit. One of the employees was in the excavation and was touching the boring equipment. The crane's load line contacted a 12.47-kilovolt overhead power line. The employee in contact with the boring equipment was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, CONSTRUCTION, E C, LOAD LINE, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103233185 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.