Inspection Detail
Inspection: 103207718 - Mead Electric
Inspection Information - Office: Chicago South Area Office
Site Address:
Mead Electric
P.O.Box 941 1 Mile S.E. Of I55 Rte 6
Joliet, IL 60435
Mailing Address:
79 Moen Avenue, Rockdale, IL 60436
Union Status: Union
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/11/1990
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 05/25/1990
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360170146 |
Investigation Summary
At approximately 10:30 a.m. on April 12, 1990, Employee #1 and a coworker were preparing to make a connection on an electrical conduit at the LB joint. They were working from the third floor of the TMA Unit. Because the LB joint could not be reached from the floor decking, Employee #1 climbed out onto a steel beam approximately 4 ft below the floor decking. The coworker remained above. Although Employee #1 was wearing a safety belt attached to a 6 ft lanyard, he fell approximately 27 ft to the first floor of the unit. He died.
Keywords: STEEL BEAM, WORK RULES, SAFETY BELT, CONSTRUCTION, FALL, FALL PROTECTION, UNSTABLE POSITION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103207718 | Fatality | Other | Occupation not reported |