Powered by GoogleTranslate

Inspection Detail

Inspection: 103204152 - Tri- Con Corporation

Inspection Information - Office: Naperville Area Office

 

Inspection Nr: 103204152
Report ID: 0521400
Date Opened: 03/14/1990

Site Address:
Tri- Con Corporation
25 West 376 Chicago Avenue
Naperville, IL 60540

Mailing Address:
16710 Richmond Street, Hazelcrest, IL 60429

Union Status: Union

SIC:1623

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/21/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 06/05/1990


Related Activity
Type Activity Nr Safety Health
Accident 360120307
Referral 900988064 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $1,800 $0 $0 $0 $0 $1,800
Current Penalty $1,800 $0 $0 $0 $0 $1,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 5A0001 04/17/1990 05/17/1990 $810 $810 $0 -  
2. 01001B Serious 19260021 B06 I 04/17/1990 05/17/1990 $0 $0 $0 -  
3. 01002A Serious 19260059 E01 04/17/1990 05/17/1990 $450 $450 $0 -  
4. 01002B Serious 19260059 G08 04/17/1990 05/17/1990 $0 $0 $0 -  
5. 01002C Serious 19260059 H 04/17/1990 05/17/1990 $0 $0 $0 -  
6. 01003A Serious 19260153 F01 04/17/1990 04/20/1990 $540 $540 $0 -  
7. 01003B Serious 19260153 H08 04/17/1990 04/20/1990 $0 $0 $0 -  
8. 01003C Serious 19260153 H08 04/17/1990 04/20/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 841023
Event: 03/14/1990
ONE EMPLOYEE KILLED ANOTHER CRITICALLY INJURED IN EXPLOSION

At approximately 8:50 a.m. on March 14, 1990, Employees #1, #2, and #3 were preparing to finish pouring the floor of an underground utility vault at a water pumping station, when an explosion and flash fire occurred. The Salamander device and 100-lb propane tank had been placed in the 20-ft by 30-ft by 10.5-ft-deep vault the day before and left burning overnight to dry condensation. Upon arrival to the site, the crew discovered that the burner had gone out and the employees could smell propane gas. They attempted to ventilate the vault by leaving the hatch doors open for a while. The explosion was apparently ignited by a match struck inside the vault. Employee #1 was killed and Employee #2 was critically injured, and hospitalized as a result of the explosion.

Keywords: BURN, ELECTRICAL VAULT, POURING, HATCH, FIRE, EXPLOSION, PROPANE, TANK, DOOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103204152 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 103204152 Fatality Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.