Inspection Detail
Inspection: 103191987 - Boyles Bros. Drilling Company
Inspection Information - Office: Boise Area Office
Site Address:
Boyles Bros. Drilling Company
Gem State Hydroelectric Project, Canyon Road
Idaho Falls, ID 83402
Mailing Address:
Post Office Box 475, Idaho Falls, ID 83402
Union Status: NonUnion
SIC:1771
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 02/12/1987
Emphasis:
Case Closed: 04/03/1987
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 900653189 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $490 | $0 | $0 | $0 | $0 | $490 |
Current Penalty | $490 | $0 | $0 | $0 | $0 | $490 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100110 D10 | 02/20/1987 | 03/09/1987 | $490 | $490 | $0 | - | ||
2. | 01001B | Serious | 19260151 D01 | 02/20/1987 | 02/23/1987 | $0 | $0 | $0 | - | ||
3. | 01001C | Serious | 19260152 C04 I | 02/20/1987 | 03/09/1987 | $0 | $0 | $0 | - |
Investigation Summary
EMPLOYEES #1 THROUGH #4 WERE LOCATED IN A BUILDING ADJACENT TO A TANK WHICH STORED LP GAS. THE TANK"S VALVE CONNECTIONS WERE BROKEN WHEN THEY WERE STRUCK BY A REBAR ROD BEING DRAGGED BY A PICKUP TRUCK. A CLOUD OF FLAMMABLE VAPOR FORMED FROM THE ESCAPING LP GAS. THE CLOUD WAS IGNITED BY THE PILOT LIGHT OF AN LP GAS VAPORIZER. FLAMES ENGULFED EMPLOYEES #1 THROUGH #4 WHEN THEY TRIED LEAVE THE BUILDING THROUGH A DOOR LOCATED ABOUT 20 FEET AWAY FROM THE TANK.
Keywords: FLAMMABLE VAPORS, VALVE, BURN, FIRE, LP GAS, LPG CONTAINER, GAS LEAK
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 103191987 | Hospitalized injury | Burn/Scald(Heat) | Drillers, earth | ||
2 | 103191987 | Hospitalized injury | Burn/Scald(Heat) | Drillers, earth |