Powered by GoogleTranslate

Inspection Detail

Inspection: 103156527 - Smith Const. Co., Inc.

Inspection Information - Office: Wichita Area Office

 

Inspection Nr: 103156527
Report ID: 0729700
Date Opened: 05/16/1990

Site Address:
Smith Const. Co., Inc.
10412 E. Central
Wichita, KS 67207

Mailing Address:
P. O. Box 13213, Wichita, KS 67213

Union Status: NonUnion

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/22/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 07/16/1990


Related Activity
Type Activity Nr Safety Health
Accident 360976641
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 2 3 5
Initial Penalty $2,160 $0 $0 $0 $0 $2,160
Current Penalty $1,215 $0 $0 $0 $0 $1,215
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 06/08/1990 07/09/1990 $810 $810 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Serious 19260028 A 06/08/1990 06/11/1990 $810 $810 $0 I - Informal Settlement  
3. 01003 Serious 19260404 F06 06/08/1990 06/12/1990 $405 $540 $0 I - Informal Settlement  
4. 02001 Other 19260102 A01 06/08/1990 06/11/1990 $0 $0 $0 I - Informal Settlement  
5. 02002 Other 19260351 B03 06/08/1990 06/18/1990 $0 $0 $0 I - Informal Settlement  
6. 02003 Other 19260021 B02 06/20/1990 07/09/1990 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14422513
Event: 05/15/1990
Employee killed in fall through roof insulation

Employee #1 was a member of a five-person crew installing the roof of a steel aircraft building. He and a coworker were putting down 6 ft wide fiberglass insulating material between the structural skeleton and metal sheeting and then modular strips to permanently secure the insulation and as spacers for the metal sheeting.. Employee #1 was holding up a piece of C-channel to allow the coworker to install a modular strip when he fell backward through the insulation they had just installed. He fell 25 ft 5 in. onto a concrete floor and was killed. C-channel is iron used for weighing down the insulation on windy days, prior to installing the metal sheeting.

Keywords: HIGH WIND, INSTALLING, ROOF, WORK RULES, CONSTRUCTION, FALL, FALL PROTECTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103156527 Fatality Concussion Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.