Powered by GoogleTranslate

Inspection Detail

Inspection: 103100954 - Utility Tower Co.

Inspection Information - Office: Wichita Area Office

 

Inspection Nr: 103100954
Report ID: 0729700
Date Opened: 08/16/1988

Site Address:
Utility Tower Co.
16400 W. 61st St. N.
Colwich, KS 67030

Mailing Address:
P.O. Box 12369, Oklahoma City, OK 73157

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/16/1988

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/18/1988


Related Activity
Type Activity Nr Safety Health
Accident 360354708
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $1,610 $0 $0 $0 $0 $1,610
Current Penalty $1,610 $0 $0 $0 $0 $1,610
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 10/19/1988 11/21/1988 $490 $490 $0 I - Informal Settlement  
2. 01002 Serious 19260028 A 10/19/1988 11/21/1988 $490 $490 $0 I - Informal Settlement  
3. 01003 Serious 19260104 F 10/19/1988 11/21/1988 $420 $420 $0 I - Informal Settlement  
4. 01004 Serious 19260500 D01 10/19/1988 11/21/1988 $210 $210 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14503858
Event: 08/12/1988
Employee killed in 200 ft fall from microwave tower

Employees were removing 1,000 ft of 5 in. coaxial cable from a 1,154 ft tall radio tower. They were using a system of rigged lines and hoisting grips, which were spaced every 200 ft, to remove 200 ft of cable at a time. A safety backup line that used a barrel hitch had also been attached just below the hoisting grip to each of the three 200 ft sections that the workers had removed from the top. Employee #1 was at the 200 ft level on the tower. In preparation for sawing the cable, he had removed the cable brackets that held it to the tower. The weight of the cable, which had not yet been transferred over to the rigged lines by his coworker at the 400 ft level, was being held only by the hoisting grip. The cable came out of the hoisting grip and struck Employee #1. His safety belt link failed and he fell to the ground. Employee #1 was killed.

Keywords: COMMUNICATION TOWER, WIRE ROPE, INADEQUATE MAINT, SAFETY BELT, CONSTRUCTION, EQUIPMENT FAILURE, FALL, STRUCK BY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103100954 Fatality Bruise/Contus/Abras Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close