Inspection Detail
Inspection: 103100061 - Custom Packaging & Sales, Inc.
Inspection Information - Office: Wichita Area Office
Site Address:
Custom Packaging & Sales, Inc.
6500 W. 21st St.
Wichita, KS 67212
Mailing Address:
P.O. Box 8901, Wichita, KS 67208
Union Status: NonUnion
SIC:3272
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/17/1987
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/13/1987
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360639199 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 1 | 3 | ||
| Current Violations | 1 | 1 | 1 | 3 | ||
| Initial Penalty | $120 | $7,000 | $0 | $0 | $0 | $7,120 |
| Current Penalty | $100 | $4,600 | $0 | $0 | $0 | $4,700 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100219 F03 | 07/27/1987 | 08/03/1987 | $100 | $120 | $0 | I - Informal Settlement | ||
| 2. | 02001 | Willful | 19100303 G02 I | 07/27/1987 | 08/03/1987 | $4,600 | $7,000 | $0 | I - Informal Settlement | ||
| 3. | 03001 | Other | 19101200 E01 I | 07/27/1987 | 08/26/1987 | $0 | $0 | $0 | - |
Investigation Summary
Two employees were operating a 480-volt Stoker auger packer located in a production area. The employees were filling the machine with 11.3 kilograms of dry grout when the circuit breaker on the machine tripped. The reset button was located in a 356-millimeter by 406-millimeter motor control box with its cover removed. The box was about 318 millimeters from the machine controls. One of the employees reached out with his left hand, apparently to reset the circuit breaker, and contacted energized parts. He was electrocuted. This employee had been working as a production labor for about 3 weeks.
Keywords: E GI V, ELECTRICAL, ELECTROCUTED, UNGUARDED LIVE PARTS, CIRCUIT BREAKER, ELEC CIRC PART--MISC, ELECTRICAL BOX
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103100061 | Fatality | Electric Shock | Occupation not reported |
Translate