Powered by GoogleTranslate

Inspection Detail

Inspection: 103047767 - Watertite Roofing Co.

Inspection Information - Office: Appleton Area Office

 

Inspection Nr: 103047767
Report ID: 0521100
Date Opened: 09/21/1989

Site Address:
Watertite Roofing Co.
Rockwell International, 1005 High Ave.
Oshkosh, WI 54903

Mailing Address:
2224 N. Mason St., Appleton, WI 54914

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/26/1989

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/09/1989


Related Activity
Type Activity Nr Safety Health
Accident 360540280
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $1,560 $0 $0 $0 $0 $1,560
Current Penalty $1,250 $0 $0 $0 $0 $1,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260404 B01 I 10/04/1989 10/10/1989 $1,000 $1,000 $0 -  
2. 01001B Serious 19260405 G02 IV 10/04/1989 10/10/1989 $0 $0 $0 -  
3. 01002 Serious 19260500 F06 10/04/1989 10/10/1989 $250 $560 $0 I - Informal Settlement  
4. 02001 Other 19260059 E01 10/04/1989 11/17/1989 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 851477
Event: 09/21/1989
ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC GRINDER

Three employees were removing windows and insulating skylights. One of the employees was on the skylight framework, grinding off bolts with his personal home grinder. The other two employees were removing glass sections. While the first employee was grinding bolts, the power supply cord pulled loose from inside the handle of the grinder. The ungrounded circuit conductor contacted the frame of the grinder, and he received a severe electric shock. One of the other employees ran over and tried to pull the tool away from the injured employee. The second employee received an electric shock. The third employee also received an electric shock when he accidentally touched the grinder frame as he was pulling the grinder's attachment plug from an extension cord set. The first employee never regained consciousness and died the following day.

Keywords: GRINDER, ELECTRICAL, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC SHOCK, ELECTRIC CORD, STRAIN RELIEF

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 103047767 Non Hospitalized injury Electric Shock Roofers
2 103047767 Fatality Electric Shock Roofers
3 103047767 Non Hospitalized injury Electric Shock Insulation Workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.