Inspection Detail
Inspection: 103019287 - Ppg Industries
Inspection Information - Office: Cleveland Area Office
Site Address:
Ppg Industries
4829 Fairland Road
Barberton, OH 44203
Mailing Address:
, , 00000
Union Status: Union
SIC:2899
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/16/1990
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 02/27/1992
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360683684 | ||
Referral | 900990078 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $640 | $0 | $0 | $0 | $0 | $640 |
Current Penalty | $320 | $0 | $0 | $0 | $0 | $320 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100106 I03 II | 10/16/1990 | 10/19/1990 | $320 | $640 | $0 | 10/31/1990 | F - Formal Settlement | |
2. | 02001 | Other | 19100147 C05 I | 10/16/1990 | 10/19/1990 | $0 | $0 | $0 | 10/31/1990 | F - Formal Settlement |
Investigation Summary
On April 18, 1990, during distillation of a chemical herbicide, a runaway reaction occurred. Vapors were released through an air vent and were ignited, causing an explosion and fire. Employees #1 and #2 were seriously burned and transferred to the hospital. On May 4, 1990, Employee #1 died.
Keywords: BURN, FLAMMABLE VAPORS, FIRE, EXPLOSION, CHEMICAL REACTION, PESTICIDE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 103019287 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
2 | 103019287 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |