Inspection Detail
Inspection: 102983723 - Briggs & Stratton Corporation
Inspection Information - Office: Milwaukee Area Office
Site Address:
Briggs & Stratton Corporation
3300 North 124th Street
Wauwatosa, WI 53222
Mailing Address:
P.O. Box 702, Milwaukee, WI 53201
Union Status: Union
SIC:3519
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/20/1993
Emphasis:
Case Closed: 12/02/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360405922 |
Investigation Summary
At the start of an aluminum injection molding cycle, a hydraulic hose ruptured for an unknown reason. The stream of atomized hydraulic fluid (flash point COC greater than 500 degrees F) was ignited by the molten aluminum in a transfer container. The resulting flash fire burned Employees #1 through #9; Employees #1, #2, #3, #6, and #7 were hospitalized and a coworker was treated for shock. The hydraulic fluid was within specifications for flash point. The working pressure of the injection molding machine was below the designated working pressure of the hose and, in addition, several over-pressure devices were present on the molding machine to insure that an over-pressure condition would not occur. No external damage was noted on the hose.
Keywords: MOLTEN METAL, BURN, MOLDING MACHINE, FIRE, HYDRAULIC FLUID, EQUIPMENT FAILURE, SHOCK, CONSTRUCTION, HOSE, RUPTURE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 102983723 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate