Inspection Detail
Inspection: 102981420 - Summertime Construction Co.
Inspection Information - Office: Milwaukee Area Office
Site Address:
Summertime Construction Co.
4751 Fontana Beach Road
West Bend, WI 53095
Mailing Address:
3093 Mileview Road, West Bend, WI 53095
Union Status: NonUnion
SIC:1771
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/30/1991
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 09/30/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360573935 |
Investigation Summary
AN EMPLOYEE WAS OPERATING A CONCRETE PUMPING TRUCK DIRECTLY BENEATH A 4800-VOLT OVERHEAD POWER LINE. THE LINE WAS 32 FEET ABOVE GROUND, AND THE ARTICULATING BOOM ON THE TRUCK HAD A MAXIMUM VERTICAL REACH OF 65 FEET. THE OPERATOR WAS CONTROLLING THE BOOM WITH A CABLE-CONNECTED REMOTE CONTROL UNIT. WHILE COLLAPSING THE BOOM TO ITS STORED POSITION FOR TRAVEL, THE OPERATOR LOST SIGHT OF THE OVERHEAD LINE, PERHAPS BECAUSE OF SIX OTHER ELECTRIC AND COMMUNICATIONS LINES IN THE AREA. THE BOOM CONTACTED ONE OF THE OVERHEAD LINES, AND THE OPERATOR WAS ELECTROCUTED. HE WAS THE SOLE PROPRIETOR OF HIS SMALL (SIX-EMPLOYEE) COMPANY AND HAD NO OTHER EMPLOYEES AT THE WORKSITE.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CONCRETE TRUCK, ELECTROCUTED, E GI IA
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 102981420 | Fatality | Electric Shock | Chief exec's & gen'l administrators, public admin. |