Inspection Detail
Inspection: 102932217 - Olin-Hunt Specialty Products, Inc.
Inspection Information - Office: Allentown Area Office
Site Address:
Olin-Hunt Specialty Products, Inc.
731 Engler Road
Nazareth, PA 18064
Mailing Address:
, , 00000
Union Status: Union
SIC:2819
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/31/1992
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/08/1992
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 72714439 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 2 | 5 | |||
| Current Violations | 3 | 2 | 5 | |||
| Initial Penalty | $5,250 | $0 | $0 | $0 | $0 | $5,250 |
| Current Penalty | $3,250 | $0 | $0 | $0 | $0 | $3,250 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100120 G03 IV | 02/05/1992 | 09/06/1992 | $1,250 | $1,875 | $0 | P - Petition to Mod Abatement | ||
| 2. | 01001B | Serious | 19100120 Q02 | 02/05/1992 | 09/06/1992 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
| 3. | 01001C | Serious | 19100120 Q06 III | 02/05/1992 | 09/06/1992 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
| 4. | 01001D | Serious | 19100120 Q06 V | 02/05/1992 | 09/06/1992 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
| 5. | 01002 | Serious | 19100134 E05 I | 02/05/1992 | 02/10/1992 | $1,000 | $1,875 | $0 | I - Informal Settlement | ||
| 6. | 01003 | Serious | 19100333 B02 IVB | 02/05/1992 | 02/10/1992 | $1,000 | $1,500 | $0 | I - Informal Settlement | ||
| 7. | 02001 | Other | 19100151 B | 02/05/1992 | 02/08/1992 | $0 | $0 | $0 | - | ||
| 8. | 02002 | Other | 19100332 B01 | 02/05/1992 | 04/06/1992 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 2:15 p.m. on August 7, 1991, Employee #1 was setting up the sulfuric acid system to package out drums. He opened a diaphragm valve that would allow the acid to be transported to the drum loading area. While the valve was being opened, a Resistoflex clamped connection failed above Employee #1, and his left ear, neck, and back were covered with 90 percent sulfuric acid at ambient temperature. The Resistoflex clamped pipe system (R28788-32) had failed due to stress corrosion cracking. A company follow-up inspection found that 22 additional clamps out of an estimated 450 total had visible cracks or defects.
Keywords: LEAK, INADEQUATE MAINT, WORK RULES, EQUIPMENT FAILURE, CHEMICAL BURN, SULFURIC ACID, ACCIDENTAL DISCHARGE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 102932217 | Hospitalized injury | Burn(Chemical) | Occupation not reported |