Powered by GoogleTranslate

Inspection Detail

Inspection: 102932217 - Olin-Hunt Specialty Products, Inc.

Inspection Information - Office: Allentown Area Office

 

Inspection Nr: 102932217
Report ID: 0317900
Date Opened: 10/02/1991

Site Address:
Olin-Hunt Specialty Products, Inc.
731 Engler Road
Nazareth, PA 18064

Mailing Address:
, , 00000

Union Status: Union

SIC:2819

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/31/1992

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 10/08/1992


Related Activity
Type Activity Nr Safety Health
Complaint 72714439 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 5
Current Violations 3 2 5
Initial Penalty $5,250 $0 $0 $0 $0 $5,250
Current Penalty $3,250 $0 $0 $0 $0 $3,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100120 G03 IV 02/05/1992 09/06/1992 $1,250 $1,875 $0 P - Petition to Mod Abatement  
2. 01001B Serious 19100120 Q02 02/05/1992 09/06/1992 $0 $0 $0 P - Petition to Mod Abatement  
3. 01001C Serious 19100120 Q06 III 02/05/1992 09/06/1992 $0 $0 $0 P - Petition to Mod Abatement  
4. 01001D Serious 19100120 Q06 V 02/05/1992 09/06/1992 $0 $0 $0 P - Petition to Mod Abatement  
5. 01002 Serious 19100134 E05 I 02/05/1992 02/10/1992 $1,000 $1,875 $0 I - Informal Settlement  
6. 01003 Serious 19100333 B02 IVB 02/05/1992 02/10/1992 $1,000 $1,500 $0 I - Informal Settlement  
7. 02001 Other 19100151 B 02/05/1992 02/08/1992 $0 $0 $0 -  
8. 02002 Other 19100332 B01 02/05/1992 04/06/1992 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170340269
Event: 10/02/1991
Employee burned by leaking sulfuric acid

At approximately 2:15 p.m. on August 7, 1991, Employee #1 was setting up the sulfuric acid system to package out drums. He opened a diaphragm valve that would allow the acid to be transported to the drum loading area. While the valve was being opened, a Resistoflex clamped connection failed above Employee #1, and his left ear, neck, and back were covered with 90 percent sulfuric acid at ambient temperature. The Resistoflex clamped pipe system (R28788-32) had failed due to stress corrosion cracking. A company follow-up inspection found that 22 additional clamps out of an estimated 450 total had visible cracks or defects.

Keywords: LEAK, INADEQUATE MAINT, WORK RULES, EQUIPMENT FAILURE, CHEMICAL BURN, SULFURIC ACID, ACCIDENTAL DISCHARGE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102932217 Hospitalized injury Burn(Chemical) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close