Inspection Detail
Inspection: 102834157 - Soperton Masonry, Inc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
Soperton Masonry, Inc.
Villa South Hwy 15 South
Sandersville, GA 31082
Mailing Address:
Route 2 Box 108-B, Soperton, GA 31082
Union Status: NonUnion
SIC:1741
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/03/1988
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 05/09/1989
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360132112 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 3 | 5 | |||
| Current Violations | 2 | 3 | 5 | |||
| Initial Penalty | $330 | $0 | $0 | $0 | $0 | $330 |
| Current Penalty | $330 | $0 | $0 | $0 | $0 | $330 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 09/01/1988 | 09/08/1988 | $210 | $210 | $0 | 09/20/1988 | - | |
| 2. | 01002 | Serious | 19260102 A01 | 09/01/1988 | 09/14/1988 | $120 | $120 | $0 | 09/20/1988 | - | |
| 3. | 02001 | Other | 19260403 B02 | 09/01/1988 | 09/14/1988 | $0 | $0 | $0 | 09/20/1988 | - | |
| 4. | 02002 | Other | 19260405 A02 III | 09/01/1988 | 09/14/1988 | $0 | $0 | $0 | 09/20/1988 | - | |
| 5. | 02003 | Other | 19260405 G02 III | 09/01/1988 | 09/14/1988 | $0 | $0 | $0 | 09/20/1988 | - |
Investigation Summary
Employee #1, an electrician, was installing conduit in the back wall of a 22-room motel foundation. Two masonry employees were laying block nearby. They were approximately 27 ft away from three unbraced 8 ft 8 in high by 27 ft long by 8 ft wide finished concrete walls when a sudden rain and wind storm developed and the employees panicked. Employee #1 and one of the masonry employees ran over to one of the unbraced walls for shelter. The other masonry employee ran over to the wall and told them that they should get away from the walls. The masonry employees cleared the foundation, but Employee #1 was caught by a collapsing wall and died several hours later at the hospital. Two walls collapsed, the other remained standing.
Keywords: UNSECURED, CONCRETE, HIGH WIND, COLLAPSE, ELECTRICIAN, CONSTRUCTION, FALLING OBJECT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 102834157 | Occupation Not Listed |