Powered by GoogleTranslate

Inspection Detail

Inspection: 102759271 - Adams Thermal Systems, Inc.

Inspection Information - Office: Bismarck Area Office

 

Inspection Nr: 102759271
Report ID: 0830300
Date Opened: 10/13/2004

Site Address:
Adams Thermal Systems, Inc.
47920 Fifth Street
Canton, SD 57013

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3443

NAICS: 332313/Plate Work Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 10/13/2004

Planning Guide: Safety-Manufacturing

Emphasis: N:Amputate, S:Amputations

Case Closed: 09/14/2006


Related Activity
Type Activity Nr Safety Health
Referral 200331478 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 4 1 5
Initial Penalty $9,100 $56,000 $0 $0 $0 $65,100
Current Penalty $3,640 $22,400 $0 $0 $0 $26,040
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 02/18/2005 03/22/2005 $1,400 $3,500 $0 I - Informal Settlement  
2. 01002 Serious 19100106 E02 II 02/18/2005 03/22/2005 $420 $1,050 $0 I - Informal Settlement  
3. 01003 Serious 19100212 A01 02/18/2005 07/25/2005 $1,400 $3,500 $0 P - Petition to Mod Abatement  
4. 01004A Serious 19100215 A04 02/18/2005 03/22/2005 $420 $1,050 $0 I - Informal Settlement  
5. 01004B Serious 19100215 B09 02/18/2005 03/22/2005 $0 $0 $0 -  
6. 02001 Willful 19100212 A03 II 02/18/2005 02/24/2005 $22,400 $56,000 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200331486
Event: 09/30/2004
Employee amputates fingers while operating press brake

On September 30, 2004, Employee #1 was operating a press brake of the DR assembly machine when she reached into the point-of-operation. The rotating parts crushed four fingers on her left hand, which later were amputated at a medical center. She was hospitalized for her injuries.

Keywords: ROTATING PARTS, AMPUTATED, PRESS BRAKE, FINGER, CRUSHED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102759271 Hospitalized injury Amputation Occupation not reported
2 102759271 Non Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close