Powered by GoogleTranslate

Inspection Detail

Inspection: 102733771 - South Georgia Ice Company

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 102733771
Report ID: 0418100
Date Opened: 05/02/1990

Site Address:
South Georgia Ice Company
120 N. Central Ave.
Tifton, GA 31794

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2097

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 05/03/1990

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/30/1990


Related Activity
Type Activity Nr Safety Health
Accident 360133573
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 3 8
Current Violations 5 3 8
Initial Penalty $1,260 $0 $0 $0 $0 $1,260
Current Penalty $1,260 $0 $0 $0 $0 $1,260
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 06/26/1990 06/29/1990 $490 $490 $0 -  
2. 01002 Serious 19100147 C01 06/26/1990 07/31/1990 $210 $210 $0 -  
3. 01003 Serious 19100215 A01 06/26/1990 07/06/1990 $140 $140 $0 -  
4. 01004 Serious 19100219 E03 I 06/26/1990 07/06/1990 $280 $280 $0 -  
5. 01005A Serious 19101200 E01 06/26/1990 07/31/1990 $140 $140 $0 -  
6. 01005B Serious 19101200 G08 06/26/1990 07/31/1990 $0 $0 $0 -  
7. 01005C Serious 19101200 H 06/26/1990 07/31/1990 $0 $0 $0 -  
8. 02001 Other 19100106 D02 III 06/26/1990 07/06/1990 $0 $0 $0 -  
9. 02002 Other 19100305 G01 III 06/26/1990 07/06/1990 $0 $0 $0 -  
10. 02003 Other 19100305 J01 IV 06/26/1990 07/06/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 606558
Event: 05/01/1990
Employee crushed by falling ice and coils

Employee #1 and a coworker were chipping/removing 10 to 16 inches of ice that had built up on the brine cooling coils in a block ice storage room. When the ice and coils collapsed, they fell on top of Employee #1. He sustained a broken neck, back, pelvis, and right leg, and a compound fracture of the left ankle. Employee #1 was pronounced dead at the scene. The coworker was not injured. The ice storage room was approximately 25 by 37 feet. The coils were suspended overhead and supported by a schedule 80, 7 inch pipe structure, which was secured to the ceiling timbers.

Keywords: FRACTURE, COLLAPSE, STORAGE ROOM, BACK, CRUSHED, NECK, FALLING OBJECT, ANKLE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102733771 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close