Inspection: 102729357 - Reichhold Chemicals, Inc.

Inspection Information - Office: Atlanta West Area Office

 

Inspection Nr: 102729357
Report ID: 0418200
Date Opened: 07/15/1991

Site Address:
Reichhold Chemicals, Inc.
Rt. 4 Kensington Rd.
Kensington,, GA 30707

Mailing Address:
Rt. 4, Kensington, GA 30707

Union Status: NonUnion

SIC:2822

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/12/1991

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/03/1993


Related Activity
Type Activity Nr Safety Health
Referral 901537415 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 1 1
Initial Penalty $13,500 $0 $0 $0 $0 $13,500
Current Penalty $7,000 $0 $0 $0 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100110 B08 X 12/13/1991 12/26/1991 $4,500 $4,500 $0 01/13/1992 F - Formal Settlement Citation has been deleted.
2. 01002 Serious 19100110 B09 I 12/13/1991 12/26/1991 $7,000 $4,500 $0 01/13/1992 F - Formal Settlement  
3. 01003 Serious 19100110 B15 VI 12/13/1991 12/26/1991 $4,500 $4,500 $0 01/13/1992 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 921643
Event: 07/15/1991
Employee burned in butadiene vapor explosion

Employee #1 was unloading a rail car with approximately 32,874 gallons of butadiene at a chemical plant's tank farm. He had attached the two liquid lines and one vapor line to the dome and started unloading the car at the 402 spot. He then proceeded to secure the previously unloaded rail car at the 403 spot As he was attempting this task, the liquid line blew off the rail car at the 402 spot and sprayed butadiene into the air. The butadiene immediately formed a vapor cloud. Employee #1 ran to the pump house to shut down the pumping system when an explosion occurred, blowing him out the back door of the pump house. The fire and explosion involved three tank cars and the tank farm system. The deluge fire system activated, helping to contain the fire. Employee #1 sustained 2nd-degree burns to 30 percent of his body.

Keywords: BURN, LOADING, RAILROAD TANK CAR, FIRE, EQUIPMENT FAILURE, EXPLOSION, CHEMICAL VAPOR, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102729357 Hospitalized injury Burn(Chemical) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.