Inspection Detail
Inspection: 102729027 - Shepard Electrical Contractor
Inspection Information - Office: Atlanta East Area Office
Site Address:
Shepard Electrical Contractor
6801 Governors Lake Parkway
Norcross, GA 30071
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/11/1990
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/21/1990
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360414361 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $810 | $0 | $0 | $0 | $0 | $810 |
Current Penalty | $810 | $0 | $0 | $0 | $0 | $810 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19260417 B | 05/16/1990 | 05/19/1990 | $810 | $810 | $0 | - | ||
2. | 01001B | Serious | 19260020 B02 | 05/16/1990 | 06/20/1990 | $0 | $0 | $0 | - | ||
3. | 01001C | Serious | 19260020 B04 | 05/16/1990 | 05/19/1990 | $0 | $0 | $0 | - | ||
4. | 01001D | Serious | 19260021 B02 | 05/16/1990 | 06/20/1990 | $0 | $0 | $0 | - |
Investigation Summary
On the morning of February 27, 1990, Employee #1 acquired the independent service key for elevator #1 from building management. He then took elevator #1 to the second floor where he opened its doors, put the elevator on independent service, and installed a sign that read, "Temporarily out of service, men working below." Employee #1 returned to the elevator pit where he climbed over into the counterweight rail system. He was installing fish tape in a conduit located inside the wall when a building patron entered elevator #1 on the second floor and proceeded to move the elevator to the fifth floor. This caused the counterweights to lower, crushing Employee #1. He died.
Keywords: REPAIR, COUNTERBALANCE, CONSTRUCTION, LOCKOUT, CRUSHED, ELEVATOR, ELEVATOR SHAFT, INATTENTION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 102729027 | Fatality | Fracture | Occupation not reported |