Inspection Detail
Inspection: 102574555 - Buffalo Rock Shooters Supply, Incorporated
Inspection Information - Office: Naperville Area Office
Site Address:
Buffalo Rock Shooters Supply, Incorporated
Route 1
Ottawa, IL 61350
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3482
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/07/1988
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 03/09/1990
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360120083 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 10 | 10 | ||||
| Current Violations | 10 | 10 | ||||
| Initial Penalty | $2,920 | $0 | $0 | $0 | $0 | $2,920 |
| Current Penalty | $2,920 | $0 | $0 | $0 | $0 | $2,920 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100022 A01 | 01/09/1989 | 01/12/1989 | $280 | $280 | $0 | - | ||
| 2. | 01002 | Serious | 19100109 B01 | 01/09/1989 | 01/12/1989 | $1,000 | $1,000 | $0 | - | ||
| 3. | 01003A | Serious | 19100219 E01 I | 01/09/1989 | 01/12/1989 | $80 | $80 | $0 | - | ||
| 4. | 01003B | Serious | 19100219 E03 I | 01/09/1989 | 01/12/1989 | $0 | $0 | $0 | - | ||
| 5. | 01004 | Serious | 19100219 F01 | 01/09/1989 | 01/12/1989 | $120 | $120 | $0 | - | ||
| 6. | 01005 | Serious | 19100219 F03 | 01/09/1989 | 01/12/1989 | $120 | $120 | $0 | - | ||
| 7. | 01006 | Serious | 19100307 B | 01/09/1989 | 01/12/1989 | $1,000 | $1,000 | $0 | - | ||
| 8. | 01007 | Serious | 19101200 E01 | 01/09/1989 | 01/12/1989 | $120 | $120 | $0 | - | ||
| 9. | 01008 | Serious | 19101200 F04 | 01/09/1989 | 01/12/1989 | $40 | $40 | $0 | - | ||
| 10. | 01009 | Serious | 19101200 G01 | 01/09/1989 | 01/12/1989 | $80 | $80 | $0 | - | ||
| 11. | 01010 | Serious | 19101200 H01 | 01/09/1989 | 01/12/1989 | $80 | $80 | $0 | - |
Investigation Summary
Two consecutive explosions occurred at an ammunition manufacturing plant. Primers fed into the primer feed tube of an ammunition reloading machine appear to be the cause of the first explosion. Poor housekeeping and non-approved equipment for a class II location are the probable causes of the second explosion, in addition to the flame from the first explosion. Employees #1, #2, #3, and #4 were killed by the force of the explosion.
Keywords: EXPLOSIVES, INADEQUATE MAINT, WORK RULES, FIRE, EXPLOSION, HOUSEKEEPING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 102574555 | Fatality | Other | Occupation not reported | ||
| 2 | 102574555 | Fatality | Other | Occupation not reported | ||
| 3 | 102574555 | Fatality | Other | Occupation not reported | ||
| 4 | 102574555 | Fatality | Other | Occupation not reported |