Powered by GoogleTranslate

Inspection Detail

Inspection: 102568508 - L.T. V. Steel Company, Inc.

Inspection Information - Office: Naperville Area Office

 

Inspection Nr: 102568508
Report ID: 0521400
Date Opened: 12/17/1986

Site Address:
L.T. V. Steel Company, Inc.
Route 71
Hennepin, IL 61327

Mailing Address:
P.O. Box 325, Hennepin, IL 61327

Union Status: Union

SIC:3316

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 01/30/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 10/23/1987


Related Activity
Type Activity Nr Safety Health
Referral 900733502 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $480 $0 $0 $0 $0 $480
Current Penalty $480 $0 $0 $0 $0 $480
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 04/02/1987 05/04/1987 $480 $480 $0 J - ALJ Decision  
2. 02001A Other 19101200 F04 04/02/1987 04/17/1987 $0 $0 $0 J - ALJ Decision  
3. 02001B Other 19101200 G02 IV 04/02/1987 04/17/1987 $0 $0 $0 04/30/1987 J - ALJ Decision  
4. 02001C Other 19101200 G02 XI 04/02/1987 04/17/1987 $0 $0 $0 04/30/1987 J - ALJ Decision  

Investigation Summary

Investigation Nr: 14382089
Event: 12/15/1986
EMPLOYEE CRUSHED BETWEEN STEEL COIL AND A GENERATOR HOUSING

THE ACCIDENT OCCURRED AT THE L.T.V. STEEL COMPANY, INC.'S COLD ROLLING MILL, LOCATED APPROXIMATELY 1 MILE EAST OF HENNEPIN, ILLINOIS, AND EAST OF STATE ROUTE 71. EMPLOYEE #1 WAS STANDING 8 FEET TO THE EAST OF THE COIL INFEED CONVEYOR UPENDER, NEAR THE 500 KW GENERATOR AT THE SOUTHEAST CORNER OF THE 83 INCH COLD TEMPERING MILL. A 58,000 POUND, 83 INCH DIAMETER, 34 INCH WIDE STEEL COIL FELL OFF THE UPENDER AND ROLLED THROUGH 2 PARTLY SECURED HAND RAILS, OVER AN ELECTRIC CONTROL BOX ON 2 STEEL POSTS AND CRUSHED EMPLOYEE #1 AGAINST THE SOUTH EAST EDGE OF THE GENERATOR HOUSING.

Keywords: UNSECURED, WORK RULES, MECH MAT HANDLING, INATTENTION, CRUSHED, STRUCK BY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102568508 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.