Inspection Detail
Inspection: 102437860 - Cutler Industries, Inc.
Inspection Information - Office: Chicago North Area Office
Site Address:
Cutler Industries, Inc.
7425 Croname
Niles, IL 60648
Mailing Address:
, , 00000
Union Status: Union
SIC:3556
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 02/08/1988
Emphasis:
Case Closed: 06/01/1988
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360645279 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 4 | 5 | |||
| Current Violations | 5 | 5 | ||||
| Initial Penalty | $200 | $0 | $0 | $0 | $0 | $200 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19101200 H | 02/23/1988 | 05/27/1988 | $0 | $200 | $0 | I - Informal Settlement | ||
| 2. | 02001 | Other | 19030002 A01 | 02/23/1988 | 02/29/1988 | $0 | $0 | $0 | - | ||
| 3. | 02002 | Other | 19040005 A | 02/23/1988 | 03/14/1988 | $0 | $0 | $0 | - | ||
| 4. | 02003 | Other | 19101200 E01 I | 02/23/1988 | 03/28/1988 | $0 | $0 | $0 | - | ||
| 5. | 02004 | Other | 19101200 G01 | 02/23/1988 | 03/28/1988 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1 had worked for a previous employer from 1961 to 1979 as a field installer of commercial revolving tray ovens, some of which were insulated with asbestos-containing materials. From 1979 to 1986, he worked for the same company as a shipping clerk/inspector. He had been transferred due to unspecified health reasons. In November 1986, his employer sold one of its operations to another company, where Employee #1 worked from November 1986 to February 1987, when he went on disability. He died in November 1987. The cause of death was listed as respiratory failure and large cell carcinoma of the lung. The inspection did not reveal any causal connection between his past exposure to asbestos and his illness. No current exposure to asbestos could be documented. The former employer no longer uses asbestos. The last employer does not use asbestos in a friable form that could result in any employee exposure.
Keywords: LUNG, ASBESTOS
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 102437860 | Fatality | Cancer | Occupation not reported |