Inspection: 102422102 - Excel Operating, Inc.

Inspection Information - Office: Oklahoma City Area Office

 

Inspection Nr: 102422102
Report ID: 0627700
Date Opened: 02/20/1990

Site Address:
Excel Operating, Inc.
19 Miles North Of Okemah
Okemah, OK 74859

Mailing Address:
141 Maindale, Yukon, OK 73099

Union Status: NonUnion

SIC:1311

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/20/1990

Emphasis:

Case Closed: 03/29/1990


Related Activity
Type Activity Nr Safety Health
Accident 360444640
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $840 $0 $0 $0 $0 $840
Current Penalty $840 $0 $0 $0 $0 $840
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100147 C01 02/28/1990 04/04/1990 $280 $280 $0 -  
2. 01001B Serious 19100147 C05 I 02/28/1990 04/04/1990 $0 $0 $0 -  
3. 01002 Serious 19100303 B02 02/28/1990 04/04/1990 $280 $280 $0 -  
4. 01003 Serious 19100304 E01 III 02/28/1990 03/06/1990 $280 $280 $0 -  

Investigation Summary

Investigation Nr: 775627
Event: 02/17/1990
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

AN EMPLOYEE WAS WORKING ON AN ELECTRICALLY POWERED OIL WELL. HE WAS FOUND THE NEXT DAY BY A COWORKER. INVESTIGATION REVEALED THAT THE EMPLOYEE HAD OPENED THE SERVICE DROP FUSED DISCONNECT BOX. UNKNOWN TO THE EMPLOYEE, THE CIRCUIT CONDUCTORS WERE WIRED BACKWARDS, AND THE FUSES WERE ENERGIZED. THE EMPLOYEE INSERTED A SCREWDRIVER INTO THE BOX, APPARENTLY TO REMOVE THE FUSE, AND RECEIVED AN ELECTRIC SHOCK FROM THE 120-VOLT CIRCUIT PARTS INSIDE THE BOX. THE CURRENT ENTRY AND EXIT POINTS WERE HIS HAND AND HIS FACE. THE EMPLOYEE WAS ELECTROCUTED.

Keywords: FUSE, E GI IV, ELECTRICAL, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, ELEC CIRC PART--MISC, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102422102 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.