Inspection Detail
Inspection: 102388071 - Triangle Engineering Of Arkansas, Inc.
Inspection Information - Office: Little Rock Area Office
Site Address: 
			   Triangle Engineering Of Arkansas, Inc.
			   1101 Redmond Road
Jacksonville, AR 72076
Mailing Address: 
			   , ,  00000
Union Status: NonUnion
SIC:3444
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/27/1987
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 02/03/1988
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Accident | 360672182 | 
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total | 
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 4 | 9 | |||
| Current Violations | 5 | 4 | 9 | |||
| Initial Penalty | $640 | $0 | $0 | $0 | $0 | $640 | 
| Current Penalty | $640 | $0 | $0 | $0 | $0 | $640 | 
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 | 
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note | 
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100212 A01 | 11/23/1987 | 12/18/1987 | $80 | $80 | $0 | - | ||
| 2. | 01002 | Serious | 19100212 B | 11/23/1987 | 12/18/1987 | $200 | $200 | $0 | - | ||
| 3. | 01003 | Serious | 19100215 B09 | 11/23/1987 | 12/04/1987 | $40 | $40 | $0 | - | ||
| 4. | 01004 | Serious | 19100243 C03 | 11/23/1987 | 12/18/1987 | $160 | $160 | $0 | - | ||
| 5. | 01005 | Serious | 19100304 F04 | 11/23/1987 | 11/26/1987 | $160 | $160 | $0 | - | ||
| 6. | 02001 | Other | 19100215 A04 | 11/23/1987 | 12/04/1987 | $0 | $0 | $0 | - | ||
| 7. | 02002 | Other | 19100217 E01 I | 11/23/1987 | 12/18/1987 | $0 | $0 | $0 | - | ||
| 8. | 02003 | Other | 19100303 G02 I | 11/23/1987 | 11/26/1987 | $0 | $0 | $0 | - | ||
| 9. | 02004 | Other | 19100303 G02 II | 11/23/1987 | 12/04/1987 | $0 | $0 | $0 | - | 
Investigation Summary
As an employee of an engineering firm was reaching for a metal basket, he touched a punch press with his shoulder and was electrocuted. A safety inspection determined that, because of an electrical fault, current was flowing between the 31.8-metric-ton punch press and the metal basket, which was touching a 54.4-metric-ton punch press. Further investigation revealed that the cause of the fault was a bare connection inside a motor terminal box on a hydraulic bender located adjacent to the smaller press. A wire nut had come off a connection, and the twisted conductor ends were in contact with the motor housing. The smaller press and hydraulic bender apparently were not properly grounded.
Keywords: ELEC INSULATION, ELECTRICAL, E GI VII, ELECTROCUTED, BENDING MACHINE, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRICAL BOX, PUNCH PRESS, ELEC EQUIPMENT--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 102388071 | Fatality | Electric Shock | Occupation not reported | 
 Translate
Translate