Powered by GoogleTranslate

Inspection Detail

Inspection: 102366861 - Rykon Specialized Plating, Inc.

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 102366861
Report ID: 0524700
Date Opened: 03/24/1987

Site Address:
Rykon Specialized Plating, Inc.
555 Miller Road
Avon Lake, OH 44012

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3471

NAICS: 0 


Inspection Type: FollowUp

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/24/1987

Emphasis:

Case Closed: 03/24/1987


Related Activity
Type Activity Nr Safety Health
Inspection 101654317

Investigation Summary

Investigation Nr: 14388441
Event: 08/21/1986
EMPLOYEE KILLED HE WAS ASPHYXIATED WITH CYANIDE.

Employee #1 died in the hospital after being treated for asphyxiation due to skin absorption of cyanide from plating tanks.

Keywords: ASPHYXIATED, SKIN, CYANIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102366861 Hospitalized injury Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close