Powered by GoogleTranslate

Inspection Detail

Inspection: 102354099 - D.G. Beyer, Inc.

Inspection Information - Office: Milwaukee Area Office

 

Inspection Nr: 102354099
Report ID: 0523400
Date Opened: 04/30/1990

Site Address:
D.G. Beyer, Inc.
8237 West Brown Deer Road
Milwaukee, WI 53223

Mailing Address:
1701 North Mayfair Road, Wauwatosa, WI 53226

Union Status: Union

SIC:1542

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/11/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/24/1991


Related Activity
Type Activity Nr Safety Health
Referral 901542290 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 5 7
Current Violations 1 4 5
Initial Penalty $780 $0 $0 $0 $0 $780
Current Penalty $300 $0 $0 $0 $0 $300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 05/17/1990 05/20/1990 $300 $640 $0 F - Formal Settlement  
2. 01002 Serious 19260303 C03 05/17/1990 05/20/1990 $140 $140 $0 F - Formal Settlement Citation has been deleted.
3. 02001 Other 19030002 A01 05/17/1990 05/20/1990 $0 $0 $0 F - Formal Settlement  
4. 02002 Other 19260050 F 05/17/1990 05/20/1990 $0 $0 $0 F - Formal Settlement  
5. 02003 Other 19260059 E01 05/17/1990 05/20/1990 $0 $0 $0 F - Formal Settlement  
6. 02004 Other 19260059 F05 05/17/1990 05/20/1990 $0 $0 $0 F - Formal Settlement  
7. 02005 Other 19260404 B01 IIID 05/17/1990 05/20/1990 $0 $0 $0 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 14500425
Event: 04/30/1990
Employee severs spine in ceiling collapse

Employee #1 was standing 10 ft from the ground on a suspended cement mortar plastered ceiling that was 12 ft 8 in. wide by 38 ft long. The ceiling was held by 36 tie wires (12 rows of 3 each). Employee #1's job was to remove the ceiling section but when he cut the first row of wires the resulting stress was too much for the second through twelfth rows of tie wires, and the entire ceiling section fell to the floor. Employee #1 fell with the ceiling and, as the west end struck a one ring high scaffold, the ceiling section hinged over and sandwiched him between slabs, severing his spinal cord. The unsafe removal procedure stressed the ceiling.

Keywords: SEVERED, DISMANTLING, SPINE, CEILING, WORK RULES, OVERLOADED, TIE WIRE, CONSTRUCTION, STRUCK BY, FALLING OBJECT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102354099 Hospitalized injury Fracture Helpers, construction trades
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close