Inspection Detail
Inspection: 102311917 - Communication Graphics, Inc.
Inspection Information - Office: Oklahoma City Area Office
Site Address:
Communication Graphics, Inc.
313 North Redbud
Broken Arrow, OK 74012
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2759
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/21/1989
Emphasis:
Case Closed: 06/14/1989
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360154215 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $160 | $0 | $0 | $0 | $0 | $160 |
| Current Penalty | $160 | $0 | $0 | $0 | $0 | $160 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100212 A01 | 05/18/1989 | 05/21/1989 | $80 | $80 | $0 | - | ||
| 2. | 01002A | Serious | 19101200 E01 | 05/18/1989 | 06/22/1989 | $80 | $80 | $0 | - | ||
| 3. | 01002B | Serious | 19101200 H | 05/18/1989 | 06/22/1989 | $0 | $0 | $0 | - | ||
| 4. | 02001 | Other | 19100303 F | 05/18/1989 | 05/28/1989 | $0 | $0 | $0 | - |
Investigation Summary
An employee was replacing a curing lamp on a silk screen press. The press was in the main shop area. The established safety procedure for replacing curing lamps called for deenergizing the circuit. In violation of this procedure, the employee had bypassed at least four separate power shut off switches. He apparently contacted energized parts and was electrocuted.
Keywords: E GI IV, ELECTRICAL, WORK RULES, ELECTROCUTED, LOCKOUT, ELEC EQUIPMENT--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 102311917 | Fatality | Electric Shock | Occupation not reported |
Translate