Powered by GoogleTranslate

Inspection Detail

Inspection: 102303153 - Kannon Industrial Technologies, Inc.

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 102303153
Report ID: 0626600
Date Opened: 06/22/1988

Site Address:
Kannon Industrial Technologies, Inc.
7110 Old Katy Rd.
Houston, TX 77070

Mailing Address:
P. O. Box 691328, Houston, TX 77269

Union Status: NonUnion

SIC:3441

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/12/1988

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 10/14/1988


Related Activity
Type Activity Nr Safety Health
Accident 360345599
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 8 10
Current Violations 2 8 10
Initial Penalty $700 $0 $0 $0 $0 $700
Current Penalty $700 $0 $0 $0 $0 $700
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100252 B04 IXC 08/02/1988 08/08/1988 $350 $350 $0 -  
2. 01002A Serious 19100252 E04 IV 08/02/1988 08/08/1988 $350 $350 $0 -  
3. 01002B Serious 19100252 F02 IC 08/02/1988 08/08/1988 $0 $0 $0 -  
4. 02001 Other 19030002 A01 08/02/1988 08/09/1988 $0 $0 $0 -  
5. 02002 Other 19100020 G01 I 08/02/1988 09/06/1988 $0 $0 $0 -  
6. 02003 Other 19100020 G01 II 08/02/1988 09/06/1988 $0 $0 $0 -  
7. 02004 Other 19100020 G01 III 08/02/1988 09/06/1988 $0 $0 $0 -  
8. 02005 Other 19100020 G02 08/02/1988 09/06/1988 $0 $0 $0 -  
9. 02006 Other 19101200 E01 08/02/1988 09/06/1988 $0 $0 $0 -  
10. 02007 Other 19101200 G01 08/02/1988 09/06/1988 $0 $0 $0 -  
11. 02008 Other 19101200 H 08/02/1988 09/06/1988 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14465587
Event: 06/20/1988
ELECTRIC SHOCK - CONTACT WITH WELDING CABLE

AN EMPLOYEE WAS TACK WELDING SOME ELBOW JOINTS ON A 4-INCH-DIAMETER, 46-INCH-LONG PIPE LOCATED INSIDE OF AN 8-FOOT-6-INCH-BY-23-FOOT-2-INCH-BY-8-FOOT-6-INCH SHEET METAL SILO. THE WELDING MACHINE BEING USED WAS A LINCOLN SINGLE-PHASE, 240/480-VOLT AC ARC WELDER, WITH A MAXIMUM OPEN CIRCUIT VOLTAGE OF 76 VOLTS. THE SILO SAT ON A STRUCTURAL STEEL SKID THAT WAS GROUNDED TO A BUILDING ALONG WITH THE WELDER. THE WELDING LEADS RAN FROM THE WELDER FOR A DISTANCE OF ABOUT 50 FEET TO WHERE THE EMPLOYEE WAS WORKING. THE 45-YEAR-OLD EMPLOYEE WAS FOUND DEAD OF APPARENT ELECTROCUTION. HE HAD BURN MARKS ON THE RIGHT SIDE OF HIS TEMPLE. HE WAS FOUND LYING ON HIS BACK WITH A LEATHER GLOVE ON HIS LEFT HAND AND THE WELDING ROD HOLDER IN HIS UNGLOVED RIGHT HAND. HIS WELDING FACE SHIELD WAS UP. THE WELDING ROD WAS NEW AND HAD NOT YET STRUCK AN ARC. AT A POINT 55 INCHES FROM THE HOLDER ALONG THE WELDING LEAD CABLE WAS AN AREA WHERE THE INSULATION WAS CUT AND WHERE THE CONDUCTOR WAS EXPOSED. IT WAS HUMID THAT DAY, WITH PERIODS OF RAIN AND THUNDERSTORMS, AND THE EMPLOYEE HAD PERSPIRED ABNORMALLY.

Keywords: E GI III, ELECTRICAL, CONFINED SPACE, ELECTROCUTED, WELDER, WELDING, WELDING CABLE, WELDING ELECTRODE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102303153 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close