Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $18,000 $0 $0 $0 $0 $18,000
Current Penalty $12,600 $0 $0 $0 $0 $12,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19150012 A01 09/15/1993 09/27/1993 $3,150 $4,500 $0 I - Informal Settlement  
2. 01002 Serious 19150013 A02 09/15/1993 09/27/1993 $3,150 $4,500 $0 I - Informal Settlement  
3. 01003 Serious 19150013 B 09/15/1993 09/27/1993 $3,150 $4,500 $0 I - Informal Settlement  
4. 01004 Serious 19150152 B03 09/15/1993 09/27/1993 $3,150 $4,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170080824
Event: 07/23/1993
Employee dies in explosion

At approximately 2:00 a.m. on July 23, 1993, three employees had finished cleaning the interior of a barge. Employee #1 went back inside the barge to untie a drop light and hose. A fellow employee started pulling the light from the barge when he observed an arc from the drop light. He continued to pull on the light when he observed another arc. A loud explosion followed, killing Employee #1, who was still inside the barge. The light in use was not explosion proof.

Keywords: LONGSHORING, BARGE, ELECTRIC ARC, CLEANING, LIGHTING FIXTURE, CURRENT LEAKAGE, EXPLOSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102283744 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.