Powered by GoogleTranslate

Inspection Detail

Inspection: 102097359 - American Laser Corporation

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 102097359
Report ID: 0854910
Date Opened: 03/05/1987

Site Address:
American Laser Corporation
1832 South 3850 West
Salt Lake City, UT 84104

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3669

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/09/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/14/1987


Related Activity
Type Activity Nr Safety Health
Accident 360781272

Investigation Summary

Investigation Nr: 691550
Event: 03/05/1987
BURN - ELECTRICAL FAULT IN PANELBOARD

AN EMPLOYEE DEENERGIZED AND LOOSENED A 100-AMPERE, THREE-PHASE CIRCUIT BREAKER THAT HAD MALFUNCTIONED. HE STEPPED BACK ABOUT 2 FEET AND TALKED TO TWO OTHER PEOPLE. AFTER ABOUT 2 MINUTES, AN ELECTRICAL EXPLOSION AND FIRE ERUPTED AT THE BOTTOM OF THE PANELBOARD, 16 INCHES FROM THE CIRCUIT BREAKER. EMPLOYEE #1 SUFFERED SECOND AND THIRD DEGREE BURNS OVER 30 PERCENT OF HIS BODY. HE WAS HOSPITALIZED FOR 30 HOURS. EMPLOYEE #2 SUFFERED SMOKE INHALATION FIGHTING THE ENSUING FIRE. EMPLOYEE #3 SUFFERED MINOR FLASH BURNS AND SMOKE INHALATION. EMPLOYEES #2 AND #3 WERE TREATED AT A HOSPITAL AND RELEASED. EMPLOYEE #4 SUFFERED MINOR FLASH BURNS. SHE WAS TREATED AT THE SCENE AND RELEASED.

Keywords: BURN, ELECTRIC ARC, ELECTRICAL, E GI VII, FIRE, PANELBOARD, ELECTRICAL WORK, CIRCUIT BREAKER, ELECTRICAL FAULT, SMOKE INHALATION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102097359 Hospitalized injury Burn/Scald(Heat) Electrical and electronic technicians
2 102097359 Non Hospitalized injury Other Electrical and electronic technicians
3 102097359 Non Hospitalized injury Burn/Scald(Heat) Engineering technicians, n.e.c.
4 102097359 Non Hospitalized injury Other Electrical and electronic engineers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.