Powered by GoogleTranslate

Inspection Detail

Inspection: 102057460 - M & M Electric

Inspection Information - Office: Nv-E-Las Vegas 0953220

 

Inspection Nr: 102057460
Report ID: 0953220
Date Opened: 07/28/1987

Site Address:
M & M Electric
1380 White Dr. Lot #7, Block #10
Las Vegas, NV 89119

Mailing Address:
1380 White Dr, Las Vegas, NV 89119

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/03/1987

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 09/28/1987


Related Activity
Type Activity Nr Safety Health
Accident 36063949
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $200 $0 $0 $0 $0 $200
Current Penalty $20 $0 $0 $0 $0 $20
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260021 B02 08/28/1987 08/31/1987 $20 $200 $0 I - Informal Settlement  
2. 01001B Serious 19260450 A11 08/28/1987 08/31/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 778332
Event: 07/28/1987
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE

A supervisor asked a power line worker to help him pull up a sagging 120-volt overhead power line at a construction site. The power line worker, who had 10 years of experience, borrowed a 4.9-meter-long aluminum extension ladder to reach top of a 6.4-meter-tall utility pole to attach the sagging power line. While he was pulling the conductors, the ladder shifted, pinching a wire nut between the side rail of the ladder and the pole. The conductor contacted the ladder and energized it. The employee, who was touching the aluminum ground wire, was electrocuted. He also fell about 3.7 meters into his supervisor's arms. Another person administered cardiopulmonary resuscitation to no avail.

Keywords: ELEC PROTECT EQUIP, EXTENSION LADDER, OVERHEAD POWER LINE, ELECTRICAL, POWER LINE WORKER, ELECTROCUTED, LADDER, E PTD, METAL LADDER, ELEC UTILITY WORK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102057460 Fatality Electric Shock Electrical power installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.