Powered by GoogleTranslate

Inspection Detail

Inspection: 101969038 - Preway Industries, Inc.

Inspection Information - Office: Indiana Department Of Labor

 

Inspection Nr: 101969038
Report ID: 0551800
Date Opened: 05/27/1986

Site Address:
Preway Industries, Inc.
810 East Franklin Street
Evansville, IN 47704

Mailing Address:
P O Box 534, Evansville, IN 47704

Union Status: Union

SIC:3585

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/06/1986

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/31/1985


Related Activity
Type Activity Nr Safety Health
Accident 360199053
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $720 $0 $0 $0 $0 $720
Current Penalty $720 $0 $0 $0 $0 $720
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100217 C01 I 07/03/1986 08/04/1986 $720 $720 $0 -  
2. 02001 Other 19100217 B07 III 07/03/1986 08/04/1986 $0 $0 $0 -  
3. 02002 Other 19100217 C03 IVD 07/03/1986 08/04/1986 $0 $0 $0 -  
4. 02003 Other 19100217 F02 07/03/1986 08/04/1986 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 672287
Event: 04/28/1986
EMPLOYEE'S FINGERS AMPUTATED IN POWER PRESS

AT 7:55 AM ON APRIL 28, 1986, EMPLOYEE #1 WAS OPERATING A CLEVELAND MECHANICAL POWER PRESS #11-1, SERIAL NUMBER 8343, LOCATED IN THE PRESS DEPARTMENT (#121) AT PREWAY INDUSTRIES, INC. THE PRESS MALFUNCTIONED WHEN AN AIR VALVE, CONTROLLING THE FULL REVOLUTION CLUTCH, STUCK, CAUSING THE PRESS TO CYCLE CONTINUOUSLY. THE EMPLOYEE'S RIGHT HAND WAS CAUGHT IN THE POINT OF OPERATION WHEN HE WAS ATTEMPTING TO REMOVE A PART BEING FORMED. HIS RIGHT INDEX AND MIDDLE FINGERS WERE AMPUTATED. THE MACHINE WAS EQUIPPED WITH A PULL-OUT DEVICE AND TWO HAND TRIPS. HE EITHER WAS NOT USING THE PULL-OUT OR IT WAS NOT PROPERLY ADJUSTED. HE WAS TAKEN TO DEACONESS HOSPITAL IN EVANSVILLE FOR TREATMENT. THE FAILURE TO PROPERLY USE OR ADJUST THE POINT OF OPERATION GUARDS CAUSED THIS ACCIDENT.

Keywords: PULL BACK DEVICE, AMPUTATED, POWER PRESS, FINGER, WORK RULES, POINT OF OPERATION, PRESS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101969038 Hospitalized injury Amputation Punching and stamping press machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.