Inspection Detail
Inspection: 101951440 - Omni Electric Inc
Inspection Information - Office: Indiana Department Of Labor
Site Address:
Omni Electric Inc
(Light Pole #1b) 165th St
Hammond, IN 46320
Mailing Address:
707 Sheridan Aavenue, Michigan City, IN 46360
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/01/1986
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 10/20/1988
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360199137 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | 4 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $1,900 | $0 | $0 | $0 | $0 | $1,900 |
| Current Penalty | $500 | $0 | $0 | $0 | $0 | $500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19260021 B02 | 10/31/1986 | 11/03/1986 | $900 | $900 | $0 | 12/23/1986 | R - Review Commission | Citation has been deleted. |
| 2. | 01001B | Serious | 19260028 A | 10/31/1986 | 11/03/1986 | $500 | $0 | $0 | 12/23/1986 | R - Review Commission | |
| 3. | 01001C | Serious | 19260400 C01 | 10/31/1986 | 11/03/1986 | $0 | $0 | $0 | 12/23/1986 | - | |
| 4. | 01001D | Serious | 19260400 C02 | 10/31/1986 | 11/03/1986 | $0 | $0 | $0 | 12/23/1986 | R - Review Commission | |
| 5. | 01002A | Serious | 19260550 A15 I | 10/31/1986 | 11/03/1986 | $1,000 | $1,000 | $0 | 12/23/1986 | R - Review Commission | Citation has been deleted. |
| 6. | 01002B | Serious | 19260550 A15 IV | 10/31/1986 | 11/03/1986 | $0 | $0 | $0 | 12/23/1986 | R - Review Commission | Citation has been deleted. |
| 7. | 01002C | Serious | 19260550 A15 IV | 10/31/1986 | 11/03/1986 | $0 | $0 | $0 | 12/23/1986 | R - Review Commission | Citation has been deleted. |
| 8. | 02001 | Other | 19260550 A04 | 10/31/1986 | 11/03/1986 | $0 | $0 | $0 | 12/23/1986 | R - Review Commission | |
| 9. | 02002 | Other | 19260550 A06 | 10/31/1986 | 11/03/1986 | $0 | $0 | $0 | 12/23/1986 | R - Review Commission |
Investigation Summary
A CONSTRUCTION LABORER WAS HOLDING THE BASE OF AN ALUMINUM LIGHT POLE THAT WAS 36 FEET, 9 INCHES IN LENGTH. THE POLE WAS BEING SET ONTO AN 11-INCH-BY-11-INCH CONCRETE BASE IN THE GROUND. A PITMAN POLECAT HYDRAULIC BOOM TRUCK WAS BEING USED TO LIFT THE POLE, AND ITS LOAD LINE WAS ATTACHED AT A POINT 24 FEET FROM THE BOTTOM OF THE POLE. AS THE POLE WAS BEING STRAIGHTENED, THE LABORER HAD BOTH ARMS AROUND THE POLE TO GUIDE IT ONTO THE CONCRETE BASE. THE POLE CONTACTED A 7200-VOLT OVERHEAD POWER LINE LOCATED ABOUT 38 FEET ABOVE THE GROUND. THE LABORER WAS ELECTROCUTED AS A RESULT OF THE CONTACT.
Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, METAL POLE, E C
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 101951440 | Fatality | Electric Shock | Construction laborers |
Translate