Powered by GoogleTranslate

Inspection Detail

Inspection: 101876019 - Patton Painting Company

Inspection Information - Office: Mobile Area Office

 

Inspection Nr: 101876019
Report ID: 0418600
Date Opened: 07/21/1986

Site Address:
Patton Painting Company
Ocean Marine, Inc., 315 Powell Ave.
Bayou La Batre, AL 36509

Mailing Address:
P. O. Box 565, Bayou La Batre, AL 36509

Union Status: NonUnion

SIC:1721

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/25/1986

Planning Guide: Safety-Maritime

Emphasis:

Case Closed: 05/11/1987


Related Activity
Type Activity Nr Safety Health
Accident 360712152
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $320 $0 $0 $0 $0 $320
Current Penalty $320 $0 $0 $0 $0 $320
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19150035 B05 01/16/1987 01/23/1987 $320 $320 $0 -  
2. 01001B Serious 19150035 B05 01/16/1987 01/23/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14352918
Event: 07/21/1986
EMPLOYEES BURNED IN FIRE AND EXPLOSION ON SHIP FUEL TANK

TWO CONTRACTORS WERE WORKING INSIDE THE ENGINE ROOM OF A VESSEL UNDER CONSTRUCTION. THE PORT AND STARBOARD FUEL TANKS HAD BEEN FILLED WITH 2000 GALLONS OF #2 DIESEL FUEL. EMPLOYEE #1 WAS USING AN OXYGEN-ACETYLENE WELDING TORCH TO HEAT A PLASTIC TUBE SO IT COULD BE STRETCHED TAUT BETWEEN FITTINGS ON THE PORT FUEL TANK. A STRUCTURAL ERROR HAD BEEN MADE ON THE PORT FUEL TANK DURING FABRICATION; THERE WAS A 3/4-INCH HOLE IN THE WALL OF THE FUEL TANK WHICH HAD NOT BEEN PLUGGED. THE EMPLOYEE APARENTLY RESTED HIS WELDING TORCH IN THE HOLE AND IT IGNITED THE DIESEL FUEL VAPORS INSIDE THE TANK, RESULTING IN A FIRE AND EXPLOSION. EMPLOYEE #1 DIED OF SEVERE BURNS. EMPLOYEES #2 AND #3 WERE HOSPITALIZED WITH THIRD DEGREE BURNS. EMPLOYEE #4 WAS TREATED FOR LACERATIONS AND RELEASED.

Keywords: LEAK, DIESEL FUEL TANK, FLAMMABLE VAPORS, EXPLOSION, BURN, ACETYLENE TORCH, FIRE, SHIP

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101876019 Non Hospitalized injury Cut/Laceration Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close