Inspection Detail
Inspection: 101843613 - Willis Gray Mobile Home Service
Inspection Information - Office: Wichita Area Office
Site Address:
Willis Gray Mobile Home Service
820 Keast, Lot D-15
Hutchinson, KS 67502
Mailing Address:
Rt. #3, P.O. Box 222, Augusta, KS 67011
Union Status: NonUnion
SIC:7699
NAICS: 0
Inspection Type: Accident
Scope: No Insp/Other
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/21/1986
Emphasis:
Case Closed: 08/21/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360638803 |
Investigation Summary
An employee was drilling anchors for a mobile home. One of the anchors contacted an underground power line, and the employee was electrocuted.
Keywords: ANCHOR, ELECTRICAL, E GI VI, ELECTROCUTED, UNDRGRD POWER LINE, BLIND REACHING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 101843613 | Fatality | Electric Shock | Occupation not reported |