Inspection: 101827780 - Pine Island Electric, Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 101827780
Report ID: 0420600
Date Opened: 09/09/1986

Site Address:
Pine Island Electric, Inc.
502 Jacklin Lane
North Ft. Meyers, FL 33903

Mailing Address:
1345 Pondella Road, Suite A, North Ft. Myers, FL 33903

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/10/1986

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/06/1986


Related Activity
Type Activity Nr Safety Health
Accident 360707038
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $350 $0 $0 $0 $0 $350
Current Penalty $280 $0 $0 $0 $0 $280
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260400 C02 10/14/1986 10/20/1986 $280 $350 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14347033
Event: 09/04/1986
ELECTRIC SHOCK - GROUND FAULT IN AIR CONDITIONER

AN EMPLOYEE OF AN ELECTRICAL CONTRACTOR WAS INSTALLING A LOAD MANAGEMENT DEVICE FOR A LOCAL UTILITY. HE WAS AT A RESIDENCE (A MOBILE HOME) INSTALLING THE RADIO-CONTROLLED DEVICE TO PROVIDE ELECTRIC POWER TO A HOT WATER HEATER AND A CENTRAL AIR CONDITIONER. THE EMPLOYEE HAD INSTALLED PART OF THE UNIT AT THE HOT WATER HEATER AND WAS RUNNING WIRING TO THE AIR CONDITIONER. THE CIRCUIT FOR THE HOT WATER HEATER HAD BEEN DEENERGIZED; HOWEVER, THE CIRCUIT TO THE AIR CONDITIONER REMAINED ENERGIZED. THE EMPLOYEE WAS ELECTROCUTED WHEN HE SIMULTANEOUSLY CONTACTED THE FRAME OF THE AIR CONDITIONING UNIT AND THE WALL OF THE MOBILE HOME. THE CENTRAL AIR CONDITIONER HAD NOT BEEN GROUNDED, AND ITS COMPRESSOR HAD A GROUND FAULT IN ITS WIRING. THIS ENERGIZED THE FRAME OF THE AIR CONDITIONER AT 120 VOLTS.

Keywords: ELECTRIC MOTOR, COMPRESSOR, ELECTRICAL, AIR CONDITIONER, E GI VII, ELECTROCUTED, ELECTRICAL WORK, GROUND FAULT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101827780 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.