Inspection Detail
Inspection: 101790327 - Tommie Vaugh Motors, Inc.
Inspection Information - Office: Houston North Area Office
Site Address:
Tommie Vaugh Motors, Inc.
1145 N. Shepherd
Houston, TX 77008
Mailing Address:
P.O. Box 7495, Houston, TX 77248
Union Status: NonUnion
SIC:5511
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/11/1986
Emphasis:
Case Closed: 07/25/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360689632 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $250 | $0 | $0 | $0 | $0 | $250 |
Current Penalty | $250 | $0 | $0 | $0 | $0 | $250 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100305 A02 IIIG | 07/18/1986 | 07/22/1986 | $250 | $250 | $0 | - | ||
2. | 01001B | Serious | 19100304 F04 | 07/18/1986 | 07/22/1986 | $0 | $0 | $0 | - | ||
3. | 02001 | Other | 19100303 F | 07/18/1986 | 07/28/1986 | $0 | $0 | $0 | - |
Investigation Summary
DURING A BREAK, AN EMPLOYEE WAS SITTING ON A METAL CHAIR. ONE OF THE LEGS ON THE CHAIR WAS ON AN ENERGIZED CORD. THE LEG OF THE CHAIR HAD PENETRATED THE CORD JACKET AND THE CONDUCTOR INSULATION AND WAS CONTACTING ONE OF THE CONDUCTORS. THE EMPLOYEE HAD ONE LEG AND ONE ARM RESTING ON AN ADJACENT METAL GAS HEATER THAT WAS GROUNDED THROUGH ITS GAS SUPPLY PIPE. THE EMPLOYEE WAS ELECTROCUTED.
Keywords: ELEC INSULATION, ELECTRICAL, CHAIR, E GI VII, ELECTROCUTED, ELECTRIC CORD
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 101790327 | Fatality | Electric Shock | Occupation not reported |